February 28, 2026Nuclear Technology and Radiation Protection0 citationsOpen Access

Comparative analysis of induced radioactivity in treatment room using FLUKA Monte Carlo simulation

View Full Paper
YLY. LiLZLu ZhangXHXiaoying Han

Key Points

  • To analyze induced radioactivity from various radiation therapies in treatment rooms using FLUKA simulations.
  • Used FLUKA Monte Carlo code for simulations.
  • Modeled activity buildup with periodic irradiation approach.
  • Evaluated radioactivity levels for proton, carbon ion, and boron neutron capture therapy.
  • Air activation from all therapies is extremely low.
  • Proton and carbon ion therapies produce short-lived isotopes, with dose rates dropping below 0.1 μSv/h within 30 minutes.
  • Boron neutron capture therapy generates long-lived isotopes, leading to higher dose rates for several hours.
  • Concrete activation from proton/carbon ion therapy remains low (~10^7 Bq), while boron neutron capture therapy increases activation significantly.
  • After a week of therapy, dose rate from 24Na reaches 39.5 μSv/h, exceeding conventional limits.

Abstract

The Monte Carlo code, FLUKA, was used to compute the induced radioactivity in treatment room for proton therapy, carbon ion therapy, and boron neutron capture therapy. For modeling activity buildup, a periodic irradiation activity buildup approach was employed. Results show that air activation levels from all three therapies are extremely low. In patients, proton/carbon ion therapy mainly generates short-lived isotopes like ^15O, with dose rates at 1 m distance from patient dropping below 0. 1 \, ^-1 within 30 minutes. Boron neutron capture therapy, however, produces longer-lived isotopes (^24N, ^38Cl), leading to elevated dose rates for several hours and requiring post-treatment control measures. Notably, concrete activation diverges significantly: for proton/carbon ion therapy, the induced activity remains low (10^7 \, Bq), posing minimal risks to radiation exposure or waste disposal. Boron neutron capture therapy, by contrast, increases concrete activation by two orders of magnitude. After one week of operation, 24Na buildup causes the dose rate at the treatment room center to reach 39. 5 \, ^-1 (after 5 minute cooling) -15 times the conventional limit (2. 5 \, ^-1). After 30 years of operation and one month of shutdown, the activity of ^55Fe exceeds the exemption limit by a factor of 42. 1. This study provides key guidance for radiation shielding design, waste management, and clinical protocol optimization for advanced radiotherapy facilities.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Li et al. (2025) studied this question.

synapsesocial.com/papers/69a287350a974eb0d3c02c34https://doi.org/10.2298/ntrp2504293l
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Dosimetric study of proton boron capture therapy based on Monte Carlo simulation and machine learning algorithms2025 · 1 citations
  2. 2Specific gamma-ray dose constants for nuclides important to dosimetry and radiological assessment1982 · 65 citations
  3. 3Investigation of photon doses reaching healthy tissues in the use of different neutron energies in boron neutron capture therapy2022 · 2 citations
  4. 4Design of a BNCT irradiation room based on proton accelerator and beryllium target2020 · 10 citations