This study investigated the effects of body mass index (BMI)-related noise simulation on coronary artery calcium score (CACS) and liver fat quantification in coronary artery computed tomography (CT) images, which are acquired using X-ray-based electromagnetic radiation. Noise maps extracted from obese patients were added to normal-weight images to generate virtual high-BMI conditions, allowing assessment of noise effects independent of anatomical differences. CACS was evaluated at four locations, and liver fat was quantified using liver attenuation, liver-to-spleen (L/S) ratio, and L/S difference. Across the virtual high-BMI datasets, approximately 71% of cases showed increased CACS and 57% demonstrated upward changes in risk rank. Liver fat assessment decreased by up to 1.98%, 6.69%, and 19.02% in liver attenuation, L/S ratio, and L/ S difference, respectively. These findings indicate that BMI-related noise, arising from increased attenuation of electromagnetic X-ray photons, can influence quantitative CT metrics and should be considered in clinical CT interpretation.
Building similarity graph...
Analyzing shared references across papers
Loading...
Hajin Kim
Sewon Lim
Minji Park
Journal of Magnetics
Building similarity graph...
Analyzing shared references across papers
Loading...
Kim et al. (Wed,) studied this question.
www.synapsesocial.com/papers/69a75bbfc6e9836116a23a7f — DOI: https://doi.org/10.4283/jmag.2025.30.4.694