PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 3, 20260 citations

Pixelwise Uncertainty Quantification of Accelerated MRI Reconstruction.

IGIlias I. GiannakopoulosLMLokesh B Gautham MuthukumarYLYvonne W. Lui

Key Points

  • Our method enables identification of unreliable regions in MRI scans without needing a reference image, enhancing diagnostic confidence.
  • Quantitative results show a Pearson correlation coefficient above 90% at acceleration factors of four-fold or more, indicating model accuracy.
  • Utilizing conformal quantile regression with MRI reconstruction offers statistically rigorous uncertainty intervals, improving image evaluation outcomes.
  • The framework enhances potential adaptive MRI acquisition protocols, balancing scan times with diagnostic reliability effectively.

Abstract

Parallel imaging techniques reduce magnetic resonance imaging (MRI) scan time but image quality degrades as the acceleration factor increases. In clinical practice, conservative acceleration factors are chosen because no mechanism exists to automatically assess the diagnostic quality of undersampled reconstructions. This work introduces a general framework for pixel-wise uncertainty quantification in parallel MRI reconstructions, enabling automatic identification of unreliable regions without access to any ground-truth reference image. Our method integrates conformal quantile regression with image reconstruction methods to estimate statistically rigorous pixelwise uncertainty intervals. We trained and evaluated our model on Cartesian undersampled brain and knee data obtained from the fastMRI dataset using acceleration factors ranging from 2 to 10. An end-to-end Variational Network was used for image reconstruction. Quantitative experiments demonstrate strong agreement between predicted uncertainty maps and true reconstruction error. Using our method, the corresponding Pearson correlation coefficient was higher than 90% at acceleration levels at and above four-fold; whereas it dropped to less than 70% when the uncertainty was computed using a simpler a heuristic notion (magnitude of the residual). Qualitative examples further show the uncertainty maps based on quantile regression capture the magnitude and spatial distribution of reconstruction errors across acceleration factors, with regions of elevated uncertainty aligning with pathologies and artifacts. The proposed framework enables evaluation of reconstruction quality without access to fully-sampled ground-truth reference images. It represents a step toward adaptive MRI acquisition protocols that may be able to dynamically balance scan time and diagnostic reliability.

Ask AI
Helpful
Bookmark
Share

Cite This Study

Giannakopoulos et al. (2026) studied this question.

synapsesocial.com/papers/69a7684abadf0bb9e87e442c
Ask AI
Helpful
Bookmark
Share