March 5, 2026Дефектоскопия / Russian Journal of Nondestructive Testing0 citations

Electronic Paramagnetic Resonance and Thermoluminescence of Polytetrafluoroethylene for Control of Radiation Technologies

View Full Paper
EVE.N. Vazirova

Key Points

  • The research aims to evaluate the dosimetry method utilizing electron paramagnetic resonance and thermally stimulated luminescence in PTFE.
  • Irradiated PTFE samples with accelerated electrons at 10 MeV and doses from 10 to 50 kGy.
  • Measured the EPR and TL signal intensities post-irradiation.
  • Analyzed the correlation between EPR and TL properties and their temperature-dependent behavior.
  • EPR signal intensity showed a linear relationship with radiation dose.
  • TL parameters: T = 164 °C, form factor u = 0.45, frequency factor S = 4.44·10 s, activation energy E = 1.14 eV.
  • TL output also exhibited a linear dependence on radiation dose, with a luminescence maximum around 425 nm.

Abstract

The possibility of implementing the high-dose dosimetry method based on a combination of electron paramagnetic resonance (EPR) and thermally stimulated luminescence (TL) phenomena was investigated. Domestically produced polytetrafluoroethylene (PTFE) was used as an ionizing radiation detector. Detector samples were irradiated with accelerated electrons with an energy of 10 MeV with doses from 10 to 50 kGy. After irradiation, the intensities of the EPR and TL signals of each detector were measured. The dependence of the EPR signal intensity on the radiation dose was linear. The TL parameters were equal to: maximum temperature T = 164 °C, form factor u = 0,45, frequency factor S = 4,44·10 s, activation energy E = 1,14 eV. The spectral composition of TL had a wide band with a luminescence maximum of about 425 nm. The dose dependence of the TL output was also linear in the studied dose range. Annealing of EPR and TL signals occurred in the same temperature range, 160—240 °C. The correlation of dose dependences of normalized intensities of EPR and TL signals, the similarity of their temperature ranges of annealing intensities, indicated that the EPR and TL properties of PTFE detectors are associated with changes in the charge states of the same centers.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

E.N. Vazirova (2025) studied this question.

synapsesocial.com/papers/69a91d8dd6127c7a504c06b3https://doi.org/10.7868/s3034498025070031
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Features of Polytetrafluoroethylene Application in High-Dose Dosimetry of Accelerated Protons by the Method of Electron Paramagnetic Resonance2025
  2. 2EXPRESS: Detection and Visualization of Minor Irradiation-Induced Changes in Polytetrafluoroethylene (PTFE) Using Raman Spectroscopy2024 · 1 citations
  3. 3Detecting ultraviolet C radiation under polyethylene terephthalate (PET) packaging by thermoluminescence analysis using commercial dosimeters2024 · 2 citations
  4. 4Radiation Resistance of PET and PEN as Probed by Luminescence and Conductivity Measurements2024
  5. 5Studying the degradation of bulk PTFE into microparticles via SP ICP-MS: A systematically developed method for the detection of F-containing particles2024 · 1 citations