March 5, 2026Actuators0 citationsOpen Access

Design and High-Performance Control of a Wide-Bandwidth, Low-Current Ripple LCL-SPA for Active Magnetic Bearing

View Full Paper
SLShuo LiuJLJuming LiangJWJingbo Wei

Key Points

  • The aim is to minimize current ripple in active magnetic bearings using an innovative LCL-SPA design and control strategy.
  • Proposed an LCL filter-based switching power amplifier (LCL-SPA).
  • Developed a sensorless capacitor current feedback active damping (CCFAD) strategy.
  • Designed a high-performance LESO-based control algorithm within the LADRC framework.
  • Conducted experimental tests for validation of performance under varying conditions.
  • Achieved current ripple minimized to 20 mA at a 3 A load.
  • Demonstrated a closed-loop bandwidth of up to 2 kHz.
  • Showed effective resonance suppression without additional hardware.

Abstract

To address the issue that current ripple in traditional switching power amplifiers (SPA) for active magnetic bearing (AMB) systems is constrained by the switching frequency, this paper proposes a novel LCL filter-based switching power amplifier (LCL-SPA) along with its parameter design and high-performance control strategy. Without altering the original full-bridge topology or the switching frequency, the proposed scheme achieves superior ripple suppression. To tackle the inherent resonance problem of the LCL filter, a sensorless capacitor current feedback active damping (CCFAD) strategy is proposed. This approach effectively suppresses resonance without additional hardware sensors and ensures system stability under digital control delays. Furthermore, to overcome the limitations of traditional PI controllers in terms of the dynamic performance and parameter tuning of the LCL-SPA, a high-performance LESO-based control algorithm within the Linear Active Disturbance Rejection Control (LADRC) framework is designed. By utilizing a Linear Extended State Observer (LESO) to estimate and compensate for total lumped disturbances in real-time, the algorithm simplifies the parameter tuning process and achieves rapid current tracking with nearly zero overshoot. Experimental results demonstrate that the proposed LCL-SPA achieves extremely low current ripple across various reference currents, with the ripple minimized to 20 mA at a 3 A load. Frequency response tests confirm that the system possesses a closed-loop bandwidth of up to 2 kHz, satisfying the high dynamic requirements of magnetic bearings.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Liu et al. (2026) studied this question.

synapsesocial.com/papers/69a91db5d6127c7a504c0c5fhttps://doi.org/10.3390/act15030144
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Analysis of Control-Delay Reduction for the Improvement of UPS Voltage-Loop Bandwidth2008 · 113 citations
  2. 2System Model of Three-Level Switching Power Amplifier for Magnetic Bearing2009 · 6 citations
  3. 3Influence of Delay on System Stability and Delay Optimization of Grid-Connected Inverters With LCL Filter2014 · 253 citations
  4. 4Novel Topologies of Power Electronics Converter as Active Magnetic Bearing Drive2019 · 76 citations
  5. 5Close-Loop Current Control With Current-Sensing Resistor for Electromagnet Driven by Full-Bridge PWM Inverter2022 · 8 citations