PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 6, 20260 citations

Theoretical modeling of the effective elastic constants of a sinusoidal anti-tetra-missing rib auxetic honeycomb

View Full Paper
MZMiao ZhouXWXinxin WuYCYunjian Cheng

Key Points

  • This research aims to model the elastic constants and Poisson’s ratio of sinusoidal anti-tetra-missing rib honeycombs.
  • Developed an analytical model using the energy method within a small-deformation framework.
  • Conducted finite element simulations to validate the theoretical model.
  • Explored the relationship between geometric features and mechanical properties.
  • The model accurately predicts the experimental values for the Poisson’s ratio and elastic modulus.
  • The structure consistently maintains a negative Poisson’s ratio of approximately -0.65 regardless of variations.
  • Geometric parameter changes can tune stiffness while preserving auxetic properties.

Abstract

Anti-tetra missing rib auxetic honeycombs represent a typical class of auxetic metamaterials exhibiting pronounced negative Poisson’s ratio (NPR) effect. Conventional straight-ligament designs tend to incur stress concentrations at local nodes, whereas wavy configurations can effectively alleviate this issue. To elucidate the intrinsic relationship between microscopic geometric features and macroscopic mechanical properties, and to provide theoretical guidance for parameter-oriented structural design, this study develops an analytical model for the equivalent Poisson’s ratio and elastic modulus of a sinusoidal anti-tetra-missing rib honeycomb (SATMRH) based on the energy method within the small-deformation framework. Finite element (FE) simulations are conducted to validate the analytical formulations. The results show that the proposed model agrees well with the numerical predictions and accurately captures the influence of geometric parameters on the macroscopic equivalent mechanical properties. Moreover, it is revealed that the structure maintains a nearly constant negative Poisson’s ratio of approximately –0.65, regardless of geometric variations, allowing stiffness tuning without sacrificing auxeticity. This work offers reliable theoretical support for the structural design and performance tailoring of ligament-based anti-chiral auxetic metamaterials.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Zhou et al. (2026) studied this question.

synapsesocial.com/papers/69aa710d531e4c4a9ff5b637https://doi.org/10.1051/epjam/2026001/pdf
Ask AI
Helpful
Bookmark
Share
View Full Paper