PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 12, 20260 citations

Assessing the Diagnostic Value of Laparoscopic Port Air Content in Detecting Anastomotic Leaks After Colorectal Surgery: A Pilot Study.

View Full Paper
VAVahid AhmadiSMSeyed Hamzah MousavieHVHamed Vaseghi

Key Points

  • This study aims to evaluate the connection between air content at laparoscopic port sites and the occurrence of anastomotic leaks after colorectal surgery.
  • Included sixty patients undergoing colorectal surgery with primary anastomosis.
  • Two radiologists classified port air content as 'No Air,' 'Low,' or 'High' based on postoperative CT scans.
  • Logistic regression models predicted Clinically Identified Leak (CIL) and Surgically Confirmed Leak (SCL).
  • Patients with no air showed significantly lower CIL rates than those with low or high PAC (P < .001).
  • High PAC was a strong predictor of SCL (OR = 88.117, P = .002).
  • Both CIL and SCL showed high area under the curve metrics (0.896 and 0.898 respectively), indicating excellent model performance.

Abstract

Background and ObjectivesAnastomotic leakage (AL) is a severe complication after colorectal surgery, affecting patient outcomes. Early detection is essential, but current methods are limited. This study aimed to assess the relationship between air volume at laparoscopic port sites in early postoperative CT scans (days 3-4) and the occurrence of AL.MethodsSixty patients who underwent colorectal surgery with primary anastomosis were included. Two expert radiologists, blinded to clinical outcomes, reviewed postoperative CT scans (days 3-4) and classified port air content (PAC) as "No Air," "Low," or "High." AL was detected based on clinical and surgical criteria. Logistic regression modeling predicted Clinically Identified Leak (CIL) and Surgically Confirmed Leak (SCL).ResultsPatients with no air at port sites had significantly lower CIL rates compared to those with low or high PAC (P P = .002). The area under the receiver operating characteristic curve was high for both CIL (0.896) and SCL (0.898), indicating excellent model performance.ConclusionThe presence and volume of air at port sites on CT scans were closely associated with AL, suggesting a fast, minimally invasive method for early detection. Further research is required to confirm these findings.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Ahmadi et al. (2026) studied this question.

synapsesocial.com/papers/69b25b0996eeacc4fcec94d9https://doi.org/10.1177/15533506261433797
Ask AI
Helpful
Bookmark
Share
View Full Paper