March 13, 2026Energies0 citationsOpen Access

A Flexible Voltage-Regulation Method for Distribution Networks Based on Pseudo-Measurement-Assisted State Estimation

View Full Paper
JQJiannan QuXMXianglong MengBZBo Yang Zhang

Key Points

  • The aim is to enhance voltage regulation in unobservable distribution networks by using integrated estimation techniques.
  • Developed a state-estimation strategy combining network partitioning and pseudo-measurement construction.
  • Applied power transfer distribution factors to create pseudo-measurements for unobservable locations.
  • Deployed PMUs at partition boundary buses for optimal monitoring.
  • Used weighted least-squares method for overall state estimation.
  • Implemented flexible voltage-regulation devices for continuous adjustments.
  • Significant improvement in voltage quality across the distribution network.
  • Effective handling of state fluctuations caused by distributed generation and environmental changes.
  • Successful case studies demonstrate the practical applicability of the method.

Abstract

To address the unobservability of distribution networks caused by insufficient coverage of measurement terminals as well as communication failures and missing data, and to cope with operating-state fluctuations induced by distributed generation integration and external environmental disturbances, this paper proposes an integrated state-estimation and voltage-regulation strategy that combines distribution-network-partitioning-based optimal PMU placement with pseudo-measurement construction using power transfer distribution factors (PTDFs). First, nodal reactive-power sensitivity information is derived from the power-flow Jacobian matrix, and an improved modularity function is employed to obtain the optimal partitioning of the distribution network, based on which PMUs are deployed at partition boundary buses. Second, PTDF-based power pseudo-measurements are constructed for unobservable buses and incorporated into the measurement model via a measurement transformation; a weighted least-squares method is then adopted to achieve system-wide state estimation. Finally, the estimated voltage states are fed into flexible voltage-regulation devices to enable fast and continuous voltage adjustment across buses. Case studies on the IEEE 33-bus system demonstrate that the proposed method effectively improves voltage quality.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Qu et al. (2026) studied this question.

synapsesocial.com/papers/69b3aca302a1e69014cce826https://doi.org/10.3390/en19061405
Ask AI
Helpful
Bookmark
Share
View Full Paper