PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 14, 2026Scientific Reports0 citationsOpen Access

Demonstration of a Gandolfi-type attachment for fast high-resolution synchrotron XRD of non-ideal specimens

View Full Paper
SKShintaro KobayashiSKShogo KawaguchiYMYuki Mori

Key Points

  • This work aims to improve the collection of high-quality PXRD data from non-ideal specimens, including molten and coarse samples.
  • Developed a Gandolfi-type attachment for a high-resolution powder diffractometer.
  • Implemented a two-axis rotation with a tilted φ-axis and ω-axis.
  • Used fast area detectors for sub-second continuous imaging in PXRD analysis.
  • Demonstrated significant improvement in data quality for molten Zn and LiCoO2 in situ synthesis.
  • Achieved reliable PXRD measurements for mineral crystals despite coarse crystallite sizes.
  • Enhanced reproducibility of data collection for non-pulverized samples.

Abstract

Abstract Synchrotron powder X-ray diffraction (PXRD) offers significant advantages in the structural analysis of functional materials and enables the acquisition of high-quality data; however, accurate data collection remains challenging for samples consisting of coarse crystallites or molten samples. Specifically, obtaining reliable PXRD data from samples in their as-solidified or non-pulverized state remains challenging during melting–solidification and crystal grain growth processes, as well as for materials produced by these processes. To mitigate these limitations, a two-axis rotation Gandolfi-type attachment—comprising a 45°-tilted φ -axis and its rotational ω -axis—was developed and implemented on a high-resolution powder diffractometer at SPring-8, which is equipped with fast area detectors. This configuration improved the particle statistics by increasing the number of crystallites satisfying the Bragg condition through two-axis rotation, while also stabilizing the sample position, even for molten samples, owing to the tilted geometry. Specifically, the integration of a high-speed spinner and multiple two-dimensional photon-counting detectors allowed sub-second continuous imaging and frame-by-frame peak separation, facilitating the indexing of PXRD data for complex structures. The analytical capability was evaluated in three case studies, namely the pair distribution function analysis of molten Zn, in situ observations of LiCoO 2 electrode material synthesis in a molten flux, and high-resolution PXRD of mineral crystals within a short timeframe. The results confirmed that the Gandolfi-type attachment improved data quality and reproducibility, thereby enabling reliable measurements even for practical samples with limited availability of fine powders.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Kobayashi et al. (2026) studied this question.

synapsesocial.com/papers/69b4ad9a18185d8a398012e4https://doi.org/10.1038/s41598-026-43550-4
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1High-throughput and high-resolution powder X-ray diffractometer consisting of six sets of 2D CdTe detectors with variable sample-to-detector distance and innovative automation system2024 · 36 citations
  2. 2The fast azimuthal integration Python library: pyFAI2015 · 919 citations
  3. 3Application of the Quantitative-Phase and Crystal-Structure Simultaneous Analysis to the X-ray Diffraction Data Obtained by Synchrotron Gandolfi Camera System2007 · 2 citations
  4. 4Limiting Factors for Diffraction in the Gandolfi X-Ray Camera1988 · 2 citations
  5. 5LiCoO2: formation, structure, lithium and oxygen nonstoichiometry, electrochemical behaviour and transport properties2004 · 353 citations