March 14, 2026Energies0 citationsOpen Access

Preliminary Experimental Investigation of the Performance of a Horizontal Air-Ground Heat Exchanger Integrated with Peltier Cells—The AIRcon.WATER Project

View Full Paper
GFGianluca Falcicchia FerraraCBCristina BaglivoGRGiulio Russo

Key Points

  • This work aims to investigate the efficiency and limitations of a new air conditioning system using Peltier cells integrated with a horizontal air-ground heat exchanger.
  • Developed and tested a laboratory-scale prototype of an air conditioning system.
  • Conducted tests under controlled conditions with varying configurations.
  • Measured temperature changes and system performance at different voltage levels and airflow velocities.
  • Achieved average temperature increases of approximately +1.9 °C on the hot flow.
  • Observed decreases in cold flow temperatures ranging from −1.0 °C to −1.7 °C.
  • Found that airflow velocity and applied voltage significantly influence system performance.

Abstract

This work experimentally investigates the behavior of a new indoor air conditioning system based on the application of Peltier cells in a Horizontal Air–Ground Heat Exchanger (HAGHE). To this end, a laboratory-scale prototype focusing exclusively on the terminal section of the system was developed and tested under controlled conditions. A series of configurations was tested, each representing an evolution of the previous one. The results highlight the strong dependence of system performance on airflow velocity, applied voltage, and heat dissipation effectiveness, demonstrating both the potential and the critical limitations of the proposed configurations. The most promising results were obtained in the advanced (fourth and fifth) configurations, yielding average temperature increases of approximately +1.9 °C on the hot flow and decreases ranging from −1.0 °C to −1.7 °C on the cold flow at moderate total voltages (40–50 V) and higher airflow velocities (0.5–0.6 m/s). In line with the principles of the circular economy, the prototype was constructed using recycled materials, including plastic pipes and Peltier cells recovered from discarded devices.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Ferrara et al. (2026) studied this question.

synapsesocial.com/papers/69b4fbeab39f7826a300c705https://doi.org/10.3390/en19061436
Ask AI
Helpful
Bookmark
Share
View Full Paper