March 14, 2026ACS Pharmacology & Translational Science0 citations

A Simple and Robust Microfluidic Glomerular Filtration Barrier-on-a-Chip Platform for Investigating Drug-Induced Nephrotoxicity

View Full Paper
YHYeo Jin HwangCJChaewon JinHCHongsoo Choi

Key Points

  • This research aims to develop a microfluidic platform to study drug-induced nephrotoxicity affecting kidney filtration.
  • Created a microfluidic glomerular filtration barrier-on-a-chip using human glomerular cells.
  • Cultured glomerular mesangial cells, podocytes, and endothelial cells on a transwell membrane.
  • Characterized glomerular selective permeability using albumin filtration.
  • Assessed the impact of the drug doxorubicin on the glomerular filtration barrier.
  • The GFBoC enabled continuous cultivation under pump-less conditions.
  • Doxorubicin exposure resulted in notable dysfunction of the glomerular filtration barrier.
  • The platform successfully facilitated multiple parallel experiments.

Abstract

The glomerulus is the filtering unit of the kidney, and the glomerular filtration barrier (GFB) is responsible for filtering waste, retaining plasma protein, and maintaining fluid balance. Drug-induced nephrotoxicity is characterized by dysfunction of the GFB and is a main obstacle in the new therapeutic screening process. This paper presents the simple and robust SLAS (Society of Laboratory Automation and Society) standard format-based microfluidic GFB-on-a-chip (GFBoC). We formed and cultured the GFB by aligning human glomerular mesangial cells (gMCs), podocytes, and glomerular endothelial cells (gECs) on each side of a conventional transwell membrane as the glomerular basement membrane (GBM). This provides facile loading/unloading of the GFB transwell into the microfluidic chip, enabling its cultivation under pump-/tubing-less perfusion flow and additional off-chip bioanalysis. It also allows various and multiple experiments in parallel in a conventional incubator at moderate operation complexity. Glomerular selective permeability of the GFB was characterized by filtration and leakage of the representative macromolecule, albumin, via the GFB, while the drug doxorubicin affected the GFB during cultivation in the GFBoC. This demonstrated that the GFBoC has potential as a simple, robust, and efficient platform for the multiple testing of nephrotoxicity and kidney disease drugs in parallel.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Hwang et al. (2026) studied this question.

synapsesocial.com/papers/69b4fc1fb39f7826a300cd52https://doi.org/10.1021/acsptsci.5c00663
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Organ-on-a-Chip Platform with an Integrated Screen-Printed Electrode Array for Real-Time Monitoring Trans-Epithelial Barrier and Bubble Formation2023 · 27 citations
  2. 2A Review on Drug‐Induced Nephrotoxicity: Pathophysiological Mechanisms, Drug Classes, Clinical Management, and Recent Advances in Mathematical Modeling and Simulation Approaches2020 · 45 citations
  3. 3Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)1998 · 5,290 citations
  4. 4A Novel Transwell Blood Brain Barrier Model Using Primary Human Cells2019 · 248 citations
  5. 5Microfluidic organ-on-chip system for multi-analyte monitoring of metabolites in 3D cell cultures2021 · 189 citations