March 14, 2026Sensors0 citationsOpen Access

Design and Implementation of an IoT-Based Low-Power Wearable EEG Sensing System for Home-Based Sleep Monitoring

View Full Paper
YWYan WangJCJun-Bo ChenYCYuting Chen

Key Points

  • The aim is to create a wearable EEG system for efficient home-based sleep monitoring with low power consumption.
  • Designed a single-channel EEG system with low-noise specifications
  • Integrated TI ADS1298 analog front-end with STM32F4 microcontroller
  • Deployed a lightweight deep learning model on a cloud backend
  • Conducted field trials with healthy subjects to test system reliability
  • Achieved an average power consumption of 150.85 mW for over 24.6 hours of operation
  • Obtained overall accuracy of 79.3% with F1-score of 88.3% for Deep Sleep (N3)
  • Validated system stability with a valid data rate exceeding 97% and Bluetooth packet loss rate of 0.8%

Abstract

Long-term home-based sleep monitoring requires wearable sensing devices that strictly balance signal precision with power constraints. This study presents the design and implementation of a low-noise, low-power wearable single-channel electroencephalography (EEG) system for automatic sleep staging. The hardware architecture integrates a TI ADS1298 analog front-end with an STM32F4 microcontroller, utilizing differential sampling and hardware-based filtering to effectively suppress power-line interference and baseline drift. System-level testing demonstrates an average power consumption of approximately 150.85 mW, enabling over 24.6 h of continuous operation on a 1000 mAh battery, which meets the requirements for overnight monitoring. To achieve accurate staging without draining the wearable’s battery, we adopted and deployed a lightweight deep learning model, SleePyCo, on the cloud backend. This architecture was specifically optimized for our edge–cloud collaborative execution, which combines contrastive representation learning with temporal dependency modeling. Validation on the ISRUC dataset yielded an overall accuracy of 79.3% ± 3.0%, with a notable F1-score of 88.3% for Deep Sleep (N3). Furthermore, practical field trials involving 10 healthy subjects verified the system’s engineering stability, achieving a valid data rate exceeding 97% and a Bluetooth packet loss rate of only 0.8%. These results confirm that the proposed hardware–software co-designed system provides a robust, energy-efficient IoMT sensing solution for daily sleep health management.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Wang et al. (2026) studied this question.

synapsesocial.com/papers/69b4fcbdb39f7826a300d745https://doi.org/10.3390/s26061803
Ask AI
Helpful
Bookmark
Share
View Full Paper