March 17, 2026Sustainable Energy Technologies and Assessments1 citationsOpen Access

Comparative energy assessment of three glazed courtyard roof designs in a cold climate heritage building

View Full Paper
ACAlejandro Cabeza-PrietoMSM. Paz Sáez-PérezMCM. Soledad Camino-Olea

Key Points

  • The aim is to compare the thermal and energy performance of three glazed roof configurations in a cold climate.
  • Conducted energy analysis using EnergyPlus and Ecotect software.
  • Evaluated three roof designs: triangulated dome, flat roof, and south-facing sawtooth roof.
  • Simulated solar exposure, annual heating and cooling demands, and daylight availability.
  • The sawtooth roof design eliminated cooling demand and maintained thermal comfort throughout the year.
  • The dome and flat roofs led to significant summer overheating and discomfort.
  • Sawtooth roof ensured daylight levels exceeded 4000 lx.

Abstract

• A comparative energy analysis of three glazed roof designs was performed. • Simulations were conducted using EnergyPlus and Ecotect in a cold climate courtyard. • The sawtooth roof eliminated cooling demand under free-running conditions. • Dome and flat roofs caused significant summer overheating and discomfort. • Results support passive design strategies for heritage retrofitting and climate resilience. The use of translucent roofs over courtyards in historic buildings has become a common strategy in rehabilitation projects. However, many of these interventions are carried out without bioclimatic or energy-efficiency criteria, leading to risks of overheating and thermal discomfort, particularly during summer. This issue is expected to worsen with climate change, compromising the habitability of these spaces. This study compares the thermal and energy performance of three glazed roof configurations: a triangulated dome, a flat roof, and a south-facing sawtooth roof with vertical glazing. The case study is a Renaissance courtyard located in Burgos, Spain (continental Mediterranean climate). Dynamic simulations using EnergyPlus and Ecotect evaluate solar exposure, annual heating and cooling demand, free-running thermal behavior, and daylight availability. Results show that roof geometry has a decisive impact on energy efficiency. The sawtooth solution eliminates cooling demand under passive operation and maintains thermal comfort (20–25 °C) throughout the year while ensuring daylight levels above 4000 lx. These findings support the use of passive geometric strategies to improve climate adaptation in enclosed heritage courtyards. The methodology is replicable in similar cold-climate contexts and offers practical guidance for energy-efficient retrofitting of historic buildings.