Personalized EMG preprocessing and normalization for musculoskeletal simulation

View Full Paper
DCDovydas CicėnasJŽJurgita ŽižienėKDKristina Daunoravičienė

Key Points

  • The study aims to create and validate a personalized EMG preprocessing pipeline for better accuracy in musculoskeletal models.
  • Collected EMG signals from six upper limb muscles using a Delsys system
  • Applied individualized spectral filtering and dual-stage normalization techniques
  • Used dynamic maximum voluntary contraction (MVC) based normalization to standardize amplitudes
  • Scaled muscle activation using functional weighting based on biomechanics
  • Input processed signals into an OpenSim elbow model for analysis
  • EMG-driven OpenSim model correlated strongly with reference data, showing coefficients over 0.98
  • Root mean square error (RMSE) for joint angles remained below 8°
  • Joint angle trajectories were consistent and physiologically plausible across trials

Abstract

Background Accurate interpretation of electromyography (EMG) signals is essential for reliable control of musculoskeletal (MS) models in biomechanics and rehabilitation applications. Conventional preprocessing methods may not account for subject-specific signal characteristics and task-related muscle function. Objective This study aimed to develop and validate an adaptive and personalized EMG preprocessing pipeline to enhance the physiological accuracy of EMG-driven musculoskeletal models during elbow flexion-extension tasks. Methods EMG signals from six upper limb muscles were recorded using a Delsys system while participants performed elbow flexion-extension movements. The signals were preprocessed using individualized spectral filtering and a dual-stage normalization approach. First, dynamic maximum voluntary contraction (MVC) based min–max normalization was applied to standardize signal amplitudes. Second, functional weighting was used to scale each muscle's activation based on its biomechanical contribution to the movement. The processed signals were used as input to an OpenSim elbow model, and resulting joint kinematics were compared to reference motion data captured by an Xsens system. Results The EMG-driven OpenSim model showed strong agreement with the Xsens data, with correlation coefficients exceeding 0.98 and root mean square error (RMSE) values below 8°. While a minor systematic offset was observed, joint angle trajectories remained consistent and physiologically plausible across trials. Conclusion The proposed subject-specific EMG preprocessing pipeline enhances the accuracy and interpretability of biomechanical models. Future research should explore adaptive signal alignment techniques and AI-based processing methods to improve model robustness in dynamic and wearable scenarios.