March 29, 2026Journal of Solid State Electrochemistry0 citationsOpen Access

Sustainable electrochemical detection of catechol using a CuO@Polyaniline Nanocomposite: optimization and analytical performance via Box–Behnken design

JWJassem WannassiPSPedro SalazarSCSoledad Carinelli

Key Points

  • The primary aim is to optimize and assess the electrochemical performance of a CuO@Polyaniline nanocomposite sensor for catechol detection.
  • Modified a glassy carbon electrode using a CuO@PANI nanocomposite.
  • Characterized the composite via FT-IR, XRD, TGA, BET, and SEM-EDX.
  • Utilized electrochemical techniques like EIS, DPV, and CV for performance assessment.
  • Employed Box-Behnken design for optimizing experimental variables.
  • Achieved excellent sensitivity of 17.823 A/M for catechol detection.
  • Established a broad linear range from 0.001 to 10 µM.
  • Obtained a low limit of detection at approximately 1 nM.
  • Confirmed recoveries between 98% and 103% during interference tests.

Abstract

A copper oxide-based polyaniline nanocomposite (CuO@PANI) was used to modify a glassy carbon electrode (GCE) in order to create an electrochemical sensor, synthesized via in situ oxidative polymerization. The methods of Fourier transform infrared spectroscopy (FT-IR), X-ray Diffraction (XRD), thermogravimetric analysis (TGA), Brunauer-Emmett-Teller (BET) area of measurement analysis and scanning electron microscopy combined with energy-dispersive X-ray spectroscopy (SEM-EDX) were used to thoroughly characterize the composite, including elemental mapping. These characterizations confirmed enhanced structural integrity, increased surface area and improved electrical conductivity arising from the presence of CuO nanoparticles and polyaniline. Electrochemical impedance spectroscopy (EIS), differential pulse voltammetry (DPV) and cyclic voltammetry (CV) were used to assess the improved electrode’s electrochemical performance, demonstrating significantly enhanced electron transfer kinetics and excellent electrochemical responsiveness. Box-Behnken methodology was used for the simultaneous optimization of the main experimental variables, therefore the optimal conditions were pH: 7.18, casting solution volume: 13 µL, drying time: 3.25 h, and accumulation time: 4.49 min. DPV measurements, after optimization, showed excellent sensitivity (17.823 A/M) and a broad linear range (0.001-10 µM) with a low limit of detection of about 1 nM. Interference and recoveries (98%-103%) tests confirmed the outstanding properties of the proposed sensor and the possibility to be used in real application for catechol contamination in environmental applications.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Wannassi et al. (2026) studied this question.

synapsesocial.com/papers/69c8c115de0f0f753b39badbhttps://doi.org/10.1007/s10008-026-06569-1
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1High-sensitivity detection of copper ions using an electrochemical sensor based on in-situ electrodeposited polyaniline nanoparticles2026
  2. 2Electrochemical Performance of Polyaniline‐Polyvanadate‐Copper Nanomaterials for the Detection of Benzoic Acid2024 · 1 citations
  3. 3Silver@copper-polyaniline nanotubes: Synthesis, characterization and biosensor analytical study2024 · 26 citations
  4. 42‐Dimensional Magnesium Oxide/Polyaniline Nanocomposite Modified Glassy Carbon Electrode for Electrochemical Detection of Dopamine and 4‐Nitrophenol2024 · 4 citations
  5. 5Sensitive Electrochemical Sensing Properties for Cyanide Detection Using Polyaniline/Cu-Vanadate Nanobelt-modified Electrode2024