March 31, 2026Journal of Biomechanics0 citationsOpen Access

The effect of interposition arthroplasty on the contact mechanics of the elbow joint

View Full Paper
CPChristoph-Johannes PucherFLFabian LanzerathSKStephanie L. Kahmann

Key Points

  • The study aims to assess how interposition arthroplasty with different grafts affects elbow joint mechanics.
  • Utilized ten fresh-frozen human elbow specimens
  • Performed static axial loading of 50–400 N at 20° flexion
  • Analyzed contact pressure using digital pressure mapping sensors
  • Compared outcomes of Achilles tendon and fascia lata grafts
  • Interposition of grafts significantly reduced peak joint pressure (p = 0.003)
  • High-pressure area (> 1 MPa) decreased significantly (p = 0.002)
  • Increased contact area observed after AT graft at high axial loads (p = 0.045)
  • No significant differences in force transmission between grafts (p = 0.089)

Abstract

Dysfunctional elbow osteoarthritis poses a therapeutic dilemma in young patients with high activity levels and corresponding demands on elbow mobility. In selected cases, interposition arthroplasty of the elbow remains a viable salvage option and alternative to primary prosthetic replacement. The primary objective of this study was to evaluate the effects of interposition arthroplasty on elbow joint contact mechanics, comparing Achilles tendon (AT) and fascia lata (FL) grafts. Ten fresh-frozen human elbow specimens underwent static axial loading (50–400 N) at 20° flexion in native state and following AT and FL graft interposition. Contact pressure distributions were analyzed using intraarticular digital pressure mapping sensors. The interposition of AT and FL grafts resulted in a significant reduction of the peak joint pressure (p = 0.003) and the high-pressure area with a contact pressure > 1 MPa (p = 0.002). Following interposition of the AT graft, a significantly increased contact area compared to the native joint was observed at high axial loads (p = 0.045). The relative radiocapitellar force transmission (p = 0.089) did not differ significantly between the conditions. A direct comparison of the grafts revealed no significant differences in any of the parameters examined. This study provides the first direct biomechanical comparison of AT and FL grafts for interposition arthroplasty under physiological joint loading, revealing comparable, significant reductions in peak contact pressure and novel evidence for increased load distribution independent of graft type.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Pucher et al. (2026) studied this question.

synapsesocial.com/papers/69cb64b0e6a8c024954b8cb3https://doi.org/10.1016/j.jbiomech.2026.113277
Ask AI
Helpful
Bookmark
Share
View Full Paper