A Hybrid Plasma‐Coupled Electrolysis for Direct Bio‐Applicable Solution Activation

View Full Paper
JLJiao LinJZJishen ZhangRZRusen Zhou

Key Points

  • The aim is to develop a hybrid electrolysis system that generates two distinct activated solutions with different bioactivities.
  • Developed a discharge plasma-coupled membrane electrolysis system.
  • Utilized electricity and water to produce two activated solutions simultaneously.
  • Regulated reactive species generated by plasma to tailor solution properties.
  • Anodic solution effectively inactivates Staphylococcus aureus with an acidic pH and free chlorine.
  • Cathodic solution shows selective anticancer capacity primarily due to hydrogen peroxide and quasi-neutral pH.
  • The anodic solution is not cytotoxic to cancer cells, and the cathodic solution has no bactericidal effect.

Abstract

ABSTRACT Developing biologically active solutions with high efficacy and low toxicity in a sustainable, cost‐effective manner is highly sought after yet fraught with challenges. In this study, we introduce a discharge plasma‐coupled membrane electrolysis system that utilizes electricity and water to simultaneously generate two distinct activated solutions with different bioactivities in a single process. The use of negative plasma and ion‐exchange membrane causes the acid–base balance shift in the solution, thus reinforcing H + accumulation around anodic areas while avoiding over‐alkalization at the cathodic side. Through such a coupling, reactive species generated by plasma can be regulated, allowing for better‐tailored solutions for applications: the anodic product, with an acidic pH and free chlorine, effectively inactivates Staphylococcus aureus , and the cathode one shows selective anticancer capacity, mainly due to H 2 O 2 and quasi‐neutral pH. Notably, the cathodic solution shows no bactericidal effect, and the anodic solution is not cytotoxic to cancer cells. Our findings offer insights into tailoring the properties of bioactive solutions for enhanced efficacy in targeted applications, such as bacterial disinfection and cancer therapy.