Synapse
⌘+K
Synapse
PulseExploreJournal ClubResearchersJournals
Instagram
HomeJournal ClubExplore
April 3, 2026Journal of Orthopaedic Research®

Effect of Bone Density and Lesser Tuberosity Osteotomy on Stemmed and Stemless Shoulder Arthroplasty Stability: A Biomechanical Study

View Full Paper
Ask AI
Bookmark
Share

Authors

DGDylan N. GreifPCPatrick CastleARAndrew Rodenhouse

Discussion

Loading...

Member takes

Overview

Biomechanical study evaluates shoulder arthroplasty stability concerning bone density and osteotomy, indicating safety of LTO.

Key Points

  • This study aims to determine if lesser tuberosity osteotomy affects stability in stemless shoulder arthroplasty among patients with low bone density.
  • Assessed humeral samples using a biomechanical testing device
  • Used dual-energy x-ray absorptiometry to determine bone mineral density
  • Randomized samples into three implant cohorts for analysis of micromotion and stability
  • Increased micromotion observed at 820 N axial load for stemless implants (p < 0.001)
  • Reduced torsional stability found in stemless versus stemmed implants (p < 0.001)
  • Lesser tuberosity osteotomy did not increase micromotion for any implant type
  • Decreased bone mineral density correlated with increased instability across all implants (p < 0.001)

Cite This Study

Greif et al. (2026) studied this question.

synapsesocial.com/papers/69cf5ebd5a333a821460d4c7https://doi.org/10.1002/jor.70189