April 7, 2026Foods0 citationsOpen Access

Determination of Glycidol in Soy Sauce Using p-Dimethylaminophenol Derivatization Coupled with Liquid Chromatography-Tandem Mass Spectrometry

View Full Paper
YZYifan ZhaoPWPeng WangLWLonglong Wang

Key Points

  • The aim is to develop a sensitive method for detecting glycidol in soy sauce to ensure food safety.
  • Developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method.
  • Utilized p-Dimethylaminophenol for chemical derivatization to stabilize analytes.
  • Implemented solid-phase extraction (SPE) with activated carbon to remove matrix interferences.
  • Maintained a pH of 6.5 during derivatization to prevent conversion of related contaminants.
  • Achieved broad linearity from 1 to at least 100 ng/mL with high accuracy (R2 = 0.9993).
  • Limit of detection and quantification set at 0.5 ng/mL and 1.0 ng/mL, respectively.
  • Confirmed the presence of glycidol in 11 commercial soy sauce samples, indicating its prevalence.

Abstract

Glycidol, a probable human carcinogen, remains an under-investigated process contaminant in soy sauce. This study developed a sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for its determination in this complex condiment. The approach combined chemical derivatization with p-Dimethylaminophenol hydrochloride for analyte stabilization with an optimized sample pretreatment using a custom-packed activated carbon solid-phase extraction (SPE) cartridge effectively removed matrix interferences, and performing the derivatization at pH 6.5 prevented conversion of 2- and 3-monochloropropanediol (2-MCPD and 3-MCPD) into glycidol, ensuring high specificity and accuracy. This approach shows broad linearity from 1 to at least 100 ng/mL (R2 = 0.9993), and demonstrates excellent performance, with a limit of detection and quantification of 0.5 ng/mL and 1.0 ng/mL, respectively. Application to commercial samples (n = 11) confirmed the presence of glycidol, highlighting the need for its monitoring. This work provides a robust analytical tool essential for supporting food safety surveillance of this contaminant in fermented foods.