The FPGA-dCViTrN accelerator achieved 99.25% and 99.7% ECG classification accuracy for arrhythmia detection on the MIT-BIH and PTB-XL datasets, respectively.
ECG signals from two publicly available datasets: PTB-XL and MIT-BIH arrhythmia
FPGA-based deep convolutional vision transformer network (dCViTrN) accelerator with an unsigned divide and conquer-based look-up-table oriented booth multiplier (UDC-LUT-BM)
Classification accuracy
A novel FPGA-based deep learning accelerator (FPGA-dCViTrN) achieves over 99% accuracy in classifying ECG signals for arrhythmia detection.
ABSTRACT ECG signal classification is important for the early detection of cardiovascular disorders (CVDs). The current methods have been struggling with the nonlinear complexity of ECG signals, making them inefficient for real‐time diagnostic analysis. Thus, this paper proposes a new FPGA‐based deep convolutional vision transformer network (dCViTrN) (FPGA‐dCViTrN) accelerator to detect different types of arrhythmias. While performing the ECG signal classification process, an unsigned divide, and conquer‐based look‐up‐table (LUT) oriented booth multiplier (UDC‐LUT‐BM) is used to perform complex mathematical operations of dCViTrN, like multiplication, for minimizing the complexity. Two publicly available datasets, specifically the PTB‐XL and MIT‐BIH arrhythmia, are used for experimentation. Furthermore, a variety of performance indicators, including accuracy, recall, precision, and F1‐score, are utilized to evaluate the deep learning accelerator. In addition, delay, resource utilization, and power consumption are used to assess the hardware complexity. The findings show that the FPGA‐dCViTrN design delivers 99.25% and 99.7% classification accuracy on the MIT‐BIH and PTB‐XL datasets. Overall, this research provides a robust, high‐accuracy deep‐learning model strengthened by an optimized FPGA architecture, allowing for enhanced, real time ECG classification and assessment in medical diagnostics.
Building similarity graph...
Analyzing shared references across papers
Loading...
L. Malathi
Transactions on Emerging Telecommunications Technologies
Sri Ramakrishna Institute of Paramedical Sciences
Building similarity graph...
Analyzing shared references across papers
Loading...
L. Malathi (Wed,) reported a other. The FPGA-dCViTrN accelerator achieved 99.25% and 99.7% ECG classification accuracy for arrhythmia detection on the MIT-BIH and PTB-XL datasets, respectively.
www.synapsesocial.com/papers/69d893626c1944d70ce04699 — DOI: https://doi.org/10.1002/ett.70410