April 17, 2026Eye & Contact Lens Science & Clinical Practice0 citations

Fluid Reservoir Characteristics in Established Scleral Lens Wear, Part 1—Evaluation of Fluid Reservoir Depth and Midday Fogging

View Full Paper
JFJennifer Swingle FogtMSMuriel SchornackESEllen Shorter

Key Points

  • The study aims to quantify fluid reservoir depth in scleral lens wearers and assess its impact on midday fogging.
  • Participants wore scleral lenses and were evaluated at three sites.
  • Experienced clinicians estimated fluid reservoir depth using slitlamp examinations.
  • Depth and optical density measurements were obtained via Scheimpflug imaging.
  • Mean estimated fluid reservoir depth was 265 µm, with no significant difference from the image-derived depth of 264 µm.
  • No correlation was observed between optical density of the fluid reservoir and its depth.

Abstract

Objectives: Fluid reservoir (FR) depth is an important parameter in the evaluation of scleral lens fitting, yet the range of depths compatible with successful wear, clinicians' ability to estimate depth, and implications of FR depth on midday fogging have yet to be fully elucidated. This study quantified FR depth of habitual scleral lens wearers, compared clinician estimates and image-based measurements of depth, and evaluated optical density of the FR to assess the effect of FR depth on midday fogging. Methods: Habitual scleral lens wearers consented to participate at three sites. FR depth was estimated using slitlamp evaluation by experienced examiners. Measurements of the depth and optical density of the FR were collected using Scheimpflug images. Results: The mean estimated (265±97; range: 0–500 µm) and image-derived (264±111; range: 40–555 µm) FR depths were not statistically different ( P =0.9). No correlation was found between optical density and depth of the FR. Conclusion: Successful scleral lens wear can occur with a wide range of FR depths. Experienced practitioners can accurately estimate FR depth using slitlamp examination. Midday fogging due to debris behind a scleral lens was not related to FR depth in this group of habitual wearers.