This paper presents the results of a study into the cooling efficiency of a target in a test section using a water-air spray under high heat flux conditions that is applicable to solving temperature control problems in the fusion energy, microelectronic, and metallurgical industries. Experimental studies were conducted in the ‘One-Sided Target Heating’ thermophysical test facility at the National Research University “Moscow Power Engineering Institute” (MPEI). In the experiments, the flowrates of the coolant components ranged from 0.5 to 2 l/min for water and from 2 to 100 l/min for air. It is found that this cooling system can remove heat loads as high as 10 MW/m2 from the target at relatively low pressures of the coolant components. The study demonstrates that the examined cooling method can yield heat transfer coefficients of up to 150 kW/(m2·K).
Building similarity graph...
Analyzing shared references across papers
Loading...
Zakharenkov et al. (Thu,) studied this question.
www.synapsesocial.com/papers/69e320cc40886becb653ff0a — DOI: https://doi.org/10.1134/s0869864325010263
A. Zakharenkov
A. Demidov
A. Dedov
Thermophysics and Aeromechanics
Moscow Power Engineering Institute
Building similarity graph...
Analyzing shared references across papers
Loading...