PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 22, 2026Proceedings of the Institution of Mechanical Engineers Part E Journal of Process Mechanical Engineering2 citations

Electric current redistribution and Lorentz force localization in magnetohydrodynamic flow through a sudden expansion

View Full Paper
RBRupesh BaroniyaMAManoj Arya

Key Points

  • The research aims to investigate how electric current redistributes in magnetohydrodynamic (MHD) flow through a sudden channel expansion.
  • Conducted three-dimensional numerical simulations using the MHD solver AnuPravaha.
  • Validations against benchmark cases, specifically Shercliff and Hunt's cases.
  • Analyzed the impact of Hartmann numbers ranging from 10 to 50 under different wall conditions.
  • Significant current redistribution occurs, with concentrated high current density near expansion edges.
  • Current Concentration Index increases with higher Hartmann numbers for both insulating and conducting walls.
  • Lorentz Force Localization Ratio increases, indicating enhanced electromagnetic braking confinement.

Abstract

In this study, we performed three-dimensional numerical simulations using the robust magnetohydrodynamic (MHD) solver AnuPravaha to investigate electric current redistribution in MHD flow through a suddenly expanded channel. The code performance was rigorously validated against standard benchmark cases, including Shercliff and Hunt's cases. The simulations were conducted for Hartmann number ranging from 10 to 50 under the presence of a transverse magnetic field, considering both electrically insulating and electrically conducting wall conditions. The results indicate that the sudden expansion significantly alters the electric potential field and leads to the formation of concentrated high current density zones near the expansion edges and corner regions. At low magnetic interaction, the current distribution remains relatively uniform, whereas at higher Hartmann number the current closure paths are strongly distorted, resulting in pronounced current redistribution across the expanded section and the formation of a highly localized Lorentz-force-driven electromagnetic braking region downstream of the expansion. A quantitative parameter named the Current Concentration Index (CCI) is introduced to measure current intensification within the expansion region relative to the inlet section, and CCI increases from 1.2997 to 1.5582 for insulating walls and from 1.3050 to 1.5729 for conducting walls as Hartmann number increases from 10 to 50. Similarly, the Lorentz Force Localization Ratio rises from 9.5131 to 16.4236 for insulating walls and from 4.0799 to 8.1194 for conducting walls, indicating stronger confinement of electromagnetic braking near the expansion plane.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Baroniya et al. (2026) studied this question.

synapsesocial.com/papers/69e866616e0dea528ddeac81https://doi.org/10.1177/09544089261444779
Ask AI
Helpful
Bookmark
Share
View Full Paper