PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 23, 2026Journal of Veterinary Research0 citationsOpen Access

Evaluation of the Flashtest multiplex qPCR system for rapid pre-laboratory screening for African swine fever infection

MWMarek WalczakLAL Adaszek

Key Points

  • The study aims to evaluate the effectiveness of the Flashtest qPCR system for detecting African swine fever in pigs.
  • Evaluation of the Flashtest qPCR system in ASF detection using blood samples from outbreaks and experimentally infected pigs.
  • Comparison of the Flashtest system's performance with a validated commercial qPCR assay.
  • Flashtest system achieved 97% sensitivity and 100% specificity in ASF detection.
  • The coefficient of variation was below 3.5%, indicating high reproducibility.
  • Limit of detection was estimated at 10^3 TCID 50/mL.

Abstract

Abstract Introduction African swine fever (ASF) is a devastating viral disease of domestic pigs and wild boar. As no safe vaccine is currently available, prevention relies primarily on strict biosecurity measures. Early diagnosis is essential to reduce the risk of ASF spread. Among the available methods, qPCR is considered the gold standard and is recommended by the World Organisation for Animal Health. The Flashtest system is designed to perform the complete workflow, from genetic material extraction to qPCR analysis, enabling rapid (under 1 hour) and accurate detection of various animal diseases in veterinary practice. Material and Methods In this study, the Flashtest system was evaluated in ASF detection using blood samples collected during ASF outbreaks in 2025 in Poland and samples from experimentally infected pigs. Its performance was compared with a validated commercial qPCR assay employed by the National Reference Laboratory for ASF in Poland. Results The system achieved up to 97% sensitivity, 100% specificity and reproducibility with a coefficient of variation below 3.5%. The limit of detection was estimated at 10 3 TCID 50 /mL, and a slightly reduced amplification efficiency was observed. Conclusion These results indicate that the Flashtest system reliably detects ASF in the majority of cases. Nevertheless, confirmatory testing is recommended for samples with low viral loads.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Walczak et al. (2026) studied this question.

synapsesocial.com/papers/69e9b77885696592c86eb4bfhttps://doi.org/10.2478/jvetres-2026-0022
Ask AI
Helpful
Bookmark
Share
View Full Paper