April 23, 2026Polymers0 citationsOpen Access

PLA/Collagen/Hydroxyapatite Ternary Biocomposites for Biodegradable Bone Screw Applications

View Full Paper
AUAyşegül Uzuner‐DemirRYRumeysa YıldırımHKHürol Koçoğlu

Key Points

  • The research aims to develop biodegradable bone screw prototypes using PLA-based biocomposites and evaluate their properties.
  • Produced biocomposites through melt micro-compounding and injection molding.
  • Evaluated morphological, thermal, rheological, mechanical properties, degradation behavior, and cytotoxicity.
  • Conducted tests including SEM, DSC, tensile, impact, and MTT cytotoxicity tests.
  • Hydroxyapatite enhanced stiffness while PEG improved toughness, resulting in increased impact strength.
  • Biocomposites with PEG, collagen, and HA showed accelerated mass loss during degradation tests.
  • The optimal formulation for soft bone was 70/20/10 PLA/COLL/HA/PEG/PDI, while 70/10/20 PLA/COLL/HA/PDI was better for hard bone.

Abstract

Poly(lactic acid) (PLA)-based biocomposites incorporating collagen (COLL) and hydroxyapatite (HA) were produced via melt micro-compounding and subsequent injection molding. 1,4-phenylene diisocyanate (PDI) was employed as a compatibilizer, while poly(ethylene glycol) (PEG) was used as a plasticizer. The morphological, thermal, rheological, and mechanical properties, as well as surface wettability, degradation behavior, and cytotoxicity, were comprehensively evaluated. SEM and DSC analyses revealed the phase distribution and thermal transitions, while rheological measurements showed that PEG reduced melt viscosity by increasing chain mobility. Mechanical performance was evaluated using tensile, impact, and DMA tests on standard specimens, indicating that HA primarily enhanced stiffness (elastic modulus), whereas PEG improved toughness, resulting in higher impact strength. Biodegradable bone screw prototypes were produced with the same formulations and subjected to torsion, enzymatic degradation, and MTT cytotoxicity tests. Degradation results indicated that biocomposites containing PEG, collagen, and HA exhibited accelerated mass loss. Overall, the 70/20/10 PLA/COLL/HA/PEG/PDI formulation was more suitable for soft (trabecular) bone tissue, while the 70/10/20 PLA/COLL/HA/PDI formulation showed advantages for hard (cortical) bone tissue applications.