April 24, 2026Orthopedics & TraumatologyOpen Access

Dual mobility cupを使用した人工股関節全置換術患者の脱臼整復時にIntra-prosthetic dislocationを生じた1例

View Full Paper
Ask AI
Bookmark
Share

Authors

淳福淳 福井嗣細嗣晃 細山祐渋祐太朗 渋田

Discussion

Loading...

Member takes

Overview

Case report reveals intra-prosthetic dislocation in hip replacement, suggesting careful reduction techniques.

Key Points

  • The aim is to highlight a case of intra-prosthetic dislocation during reduction of a hip replacement.
  • A case study of an 89-year-old female post-artificial hip joint replacement.
  • Reduction attempts were performed under spinal and general anesthesia with imaging evaluations afterwards.
  • Surgical intervention included a navigated revision surgery after diagnosis of intra-prosthetic dislocation.
  • Successful revision surgery with no further dislocation reported post-operation.
  • Initial reduction efforts did not restore proper alignment as confirmed by imaging studies.
  • Polyethylene bearing was found dislocated at the posterior wall of the acetabulum.

Cite This Study

福井 et al. (2026) studied this question.

synapsesocial.com/papers/69eb0899553a5433e34b3787https://doi.org/10.5035/nishiseisai.75.87