Adsorption-based thermal energy storage (ATES) offers a promising solution to mitigate the temporal mismatch between solar energy availability and residential heating demand. However, its adoption in built environments remains limited mainly due to the lack of comprehensive evaluations of long-term operation and transient behaviour at the system level, particularly when integrated with solar and building subsystems. This study presents the development, validation, and system-level integration of a novel TRNSYS component, Type 2802, designed to simulate the transient thermal behaviour of solid-gas ATES reactors using water vapour as the adsorbate. A detailed mathematical model is implemented in FORTRAN and embedded within TRNSYS. The model is experimentally validated using both data from the literature for small- and large-scale zeolite 13X reactors and in-house discharging tests with zeolite 5A and activated carbon. The model demonstrates strong predictive accuracy across diverse conditions. The resulting TRNSYS Type 2802 is general in the sense that it can easily be used to investigate different adsorbent materials, cylindrical reactor geometries, insulation effectiveness, and inlet conditions. Beyond validation, Type 2802 configured with zeolite 13X, is tested in an integrated simulation scenario using a simplified ATES system designed to meet residential space heating demand. Parametric investigations are carried out to examine the influence of charging, tank loop flow rates, and the addition of a heat recovery unit on the zeolite energy storage density (ESD) and system coefficient of performance (COP). Results reveal four optimal operating scenarios, with the highest ESD (122.83 kWh/m 3 ) and COP (0.164) achieved under the lowest flow rate conditions in the baseline model (without an HRU). Incorporating an HRU with 0.8 effectiveness improves the ESD by up to 40% and increases the COP from 0.164 to 0.337. • A new TRNSYS Type is developed to simulate solid–gas adsorption thermal storage reactors. • The model is validated against literature data and in-house experimental results. • The TRNSYS Type is integrated into a wider solar-driven heating system model. • System performance is assessed under varying air and heat transfer fluid flow rates. • Incorporating a heat recovery unit greatly enhances energy storage density and COP.
Building similarity graph...
Analyzing shared references across papers
Loading...
Shahrouzian et al. (Mon,) studied this question.
www.synapsesocial.com/papers/69f154e0879cb923c49451e8 — DOI: https://doi.org/10.1016/j.est.2026.122321
Ali Shahrouzian
Shima Najafi Nobar
Ronald E. Miller
Journal of Energy Storage
Carleton University
Building similarity graph...
Analyzing shared references across papers
Loading...