PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 2, 2026SHILAP Revista de lepidopterología0 citationsOpen Access

A Hybrid Multi-Stage Approach for Automated Retinal Vessel Extraction Using Directional Filtering and Region-Growing Reconstruction

View Full Paper
SASohrab AfrakhtehMZMohammadreza Ferdowsi ZadehZAZahra Aram

Key Points

  • This study aims to develop an automated method for extracting retinal blood vessels to improve early detection of diabetic retinopathy.
  • Developed a hybrid multi-stage approach combining noise reduction, centerline detection, and region-expansion reconstruction.
  • Evaluated the algorithm on the DRIVE dataset with metrics for accuracy, sensitivity, and specificity.
  • Compared performance against classical and deep-learning baselines.
  • Achieved an accuracy of 0.96578, sensitivity of 0.92896, and specificity of 0.98965 on the DRIVE dataset.
  • Improved accuracy by approximately 0.77% and thin-vessel sensitivity by over 1% compared to existing methods.

Abstract

Diabetic retinopathy is a major cause of blindness worldwide, and accurate retinal vessel extraction is essential for its early detection and monitoring. Manual delineation by ophthalmologists is time-consuming and susceptible to human variability, while automated segmentation remains challenged by noise, illumination changes, and weak contrast in thin vessels. This study presents a novel hybrid multi-stage approach for automated blood vessel extraction from digital retinal images. The method integrates noise reduction, multi-directional derivative–based centerline detection, and region-expansion reconstruction with noise suppression to more reliably recover fine and low-contrast vascular structures commonly missed by existing techniques. The algorithm was evaluated on the DRIVE dataset, achieving an accuracy of 0.96578, sensitivity of 0.92896, and specificity of 0.98965. Compared with leading classical and deep-learning baselines, the proposed framework achieves approximately 0.77% higher accuracy and over 1% improvement in thin-vessel sensitivity. These quantitative gains confirm the effectiveness of the hybrid stages in enhancing vessel continuity and recall. The proposed method therefore offers a robust and efficient tool for automated retinal image analysis, with potential utility in supporting early diagnosis and clinical management of diabetic retinopathy in practical screening workflows.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Afrakhteh et al. (2026) studied this question.

synapsesocial.com/papers/69f5947e71405d493afff4a3https://doi.org/10.22034/jaism.2025.552522.1165
Ask AI
Helpful
Bookmark
Share
View Full Paper