PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 2, 20260 citationsOpen Access

Water Quality Study at Educational Area in Bandar Seri Alam, Johor, Malaysia

MFMuhammad Farid Muhammad FathullahAZAzyan Zafyrah Mohd ZahidSKSiti Farahin Kamaruddin

Key Points

  • The aim is to evaluate the water quality of a detention pond for its potential as a water supply source for gardening and landscaping.
  • Conducted water quality tests on 16 sampling points around the detention pond and inflow point.
  • Measured physical parameters like temperature, pH, turbidity, and dissolved oxygen in-situ.
  • Performed laboratory testing for chemical and biological parameters according to Department of Environment guidelines.
  • Water quality parameters of the detention pond complied with Class IIB standards.
  • Physical and chemical tests confirmed suitability for gardening and landscaping activities.

Abstract

This research study is conducted to provide water quality data of detention pond at UiTM Pasir Gudang Campus (UiTMCJKPG) and to ascertain the suitability of this newly potential water supply source for gardening and landscaping activities in this campus. According to Department of Environment (DoE) Malaysia, 6 water quality parameters must be tested in order to recognize the suitability of the water quality status. These parameters are categorized into physical, chemical and biological characteristics. Based on the intended usage of this new source, the detention pond is classified under Class IIB. As such, the limit for the selected parameters is restricted under this category and must not be exceeded. 16 sampling points have been identified covering along the circumference of detention pond and the inflow point. Several water quality tests such as temperature, pH, turbidity and dissolved oxygen measurement are conducted in-situ while other parameters which mainly subjected to chemical and biological testing are determined in laboratory. The outcome of this research shows that the water quality of retention pond in UiTM Pasir Gudang (UiTMCJKPG) complied with the standard requirement of Class IIB thus making it as an accepted new source of water supply for gardening and landscaping maintenance activities.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Fathullah et al. (2026) studied this question.

synapsesocial.com/papers/69f594ca71405d493afffafahttps://doi.org/10.14419/ijet.v7i3.14.18827
Ask AI
Helpful
Bookmark
Share
View Full Paper