May 4, 2026Journal of Minimally Invasive Spine Surgery and Technique1 citationsOpen Access

L-Point Entry, Juxtapedicular, and Endplate-Parallel Trajectory (L-JET) Screw Fixation: A Novel Technique in Thoracic Spinal Tumor Surgery

SLSeunghoon LeeYKYoung Rak KimCLChang-Hyun Lee

Key Points

  • This study aims to evaluate the safety and feasibility of the L-JET technique for screw fixation in thoracic spinal tumors compared to traditional methods.
  • Comparative analysis of data from patients with thoracic extradural spinal tumors.
  • Screws placed using L-JET technique and conventional transpedicular method assessed for diameter, length, and complication rates.
  • Screw trajectory planned at 30° medial convergence.
  • L-JET group used larger screws (6.06±0.65 mm) compared to conventional group (5.74±0.80 mm, p=0.02).
  • No significant difference in screw length between the groups.
  • Complications or revision surgeries did not occur in either group.

Abstract

Objective: Thoracic pedicle screw fixation is technically demanding because of the natural variability in pedicle anatomy, a challenge that is further exacerbated in patients with spinal tumors who often have compromised pedicles. The L-point entry, juxtapedicular, and endplate-parallel trajectory (L-JET) technique was developed to provide a uniform entry point, a predictable screw trajectory, and the capacity to accommodate larger-diameter screws at levels T3–10. This study aimed to evaluate the safety and feasibility of the L-JET technique in comparison with the conventional transpedicular method.Methods: A comparative analysis of consecutively collected data was performed to evaluate outcomes associated with the L-JET technique in patients undergoing surgery for thoracic extradural spinal tumors. The L-point was defined as the intersection of a vertical line along the lateral margin of the facet joint and a horizontal line along the upper edge of the transverse process. The screw trajectory was planned with 30° of medial convergence in the axial plane, creating a juxtapedicular path, and a straightforward trajectory in the sagittal plane. Primary outcome measures included screw diameter, screw length, cortical breach rate, and the need for revision surgery, as assessed using computed tomography scans and medical records.Results: A total of 108 screws were placed in 22 patients using the L-JET technique, while 98 screws were placed in 18 patients using the conventional technique. The L-JET group used significantly larger-diameter screws (6.06±0.65 mm) than the conventional group (5.74±0.80 mm, p=0.02), with no significant difference observed in screw length between groups. Medial cortical breach occurred in one screw in each group, and no supra- or infrapedicular breaches were identified. No screw-related neurovascular complications or revision surgeries occurred in either group.Conclusion: The L-JET technique enables consistent screw placement with larger-diameter screws, even in compromised pedicles associated with thoracic spinal tumors, without increasing the risk of complications or the need for revision surgery.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Lee et al. (2026) studied this question.

synapsesocial.com/papers/69f836aa3ed186a739980d53https://doi.org/10.21182/jmisst.2025.02446
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1The Utility and Feasibility of Smart Glasses in Spine Surgery: Minimizing Radiation Exposure During Percutaneous Pedicle Screw Insertion2024 · 9 citations
  2. 2A Propensity Score-Matched Cohort Study Comparing 3 Different Spine Pedicle Screw Fixation Methods: Freehand, Fluoroscopy-Guided, and Robot-Assisted Techniques2024 · 8 citations
  3. 3Segmental Pedicle Screw Fixation in the Treatment of Thoracic Idiopathic Scoliosis1995 · 674 citations
  4. 4A Single-Center Experience of Robotic-Assisted Spine Surgery in Korea : Analysis of Screw Accuracy, Potential Risk Factor of Screw Malposition and Learning Curve2023 · 11 citations
  5. 5Accuracy of Pedicular Screw Placement In Vivo1990 · 1,410 citations