Enterovirus Testing in Hand, Foot, and Mouth Disease and Herpangina: A Highly Sensitive Single-Round VP4–VP2 Reverse-Transcription Polymerase Chain Reaction Assay with a Redesigned Reverse Primer

View Full Paper
TFTsuguto FujimotoMOMiki OgiKKKazuhiro Kitakawa

Key Points

  • To evaluate the sensitivity of a novel RT-PCR assay for detecting enteroviruses in clinical specimens of hand, foot, and mouth disease.
  • Developed a single-round RT-PCR assay with redesigned reverse primer (C3R) for EV detection and genotyping.
  • Tested sensitivity using EV-A71 and poliovirus type 1 reference strains.
  • Evaluated assay performance across 60 EV-positive clinical specimens.
  • C3R-based assay showed ~1000-fold higher sensitivity for EV-A71 compared to conventional assays.
  • Detected 98.3% of clinical specimens in a single-round format versus 45.0% for the conventional assay.
  • Maintained complete detection for specimens with Ct values below 40.

Abstract

Molecular typing of enteroviruses (EVs) is essential for surveillance of hand, foot, and mouth disease (HFMD). Conventional reverse-transcription polymerase chain reaction (RT-PCR) targeting the VP4–VP2 region can be insufficiently sensitive, reducing the detectability of Enterovirus A (EV-A). We developed a single-round RT-PCR assay using a modified reverse primer design (C3R) for rapid EV detection and genotyping. Sensitivity was evaluated using EV-A71 and poliovirus type 1 reference strains, across 60 EV-positive clinical specimens. The C3R-based assay showed ~1000-fold higher sensitivity for EV-A71 than for conventional assays (limit of detection: 6.6 copies/reaction). The assay detected 98.3% (59/60) of clinical specimens in a single-round format, whereas the conventional assay detected only 45.0% (27/60) and showed a marked decline in detection at higher Ct values. The C3R-based assay maintained complete detection for clinical specimens with Ct values below 40. The majority of the amplified products yielded high-quality sequences suitable for genotyping. This C3R-based RT-PCR overcomes sensitivity limitations of existing protocols and provides reliable genotyping from low-viral-load specimens, supporting its use in routine diagnostics and large-scale HFMD surveillance.