Figure 1. Serial electrocardiographic changes before and after His-bundle pacing. (A) Pre-implantation electrocardiogram demonstrating complete atrioventricular block with a slow ventricular escape rhythm and a wide QRS complex (144 ms). (B) Electrocardiogram conducted immediately after implantation showing VAT via His-bundle pacing. The paced QRS complex narrowed to 104 ms. (C) Electrocardiogram at 3-month follow-up confirmed a stable VAT mode. The intrinsically conducted QRS complex measured 93 ms. VAT, ventricular pacing with atrial triggering.
Figure 2. Changes in left atrial morphology and volume in the reported case with complete atrioventricular block. Representative images and volumetric data were derived from ECG-gated (with a standard three-lead configuration for synchronization), three-dimensional echocardiographic reconstruction via the 4D Auto LAQ module of the EchoPAC workstation (GE HealthCare). The original acquisition frame rate was >30 fps. (A,B) Static frames captured at the point of LAVmax corresponding to the peak of the ECG R-wave (end-systole), (A) before (pre) and (B) after (post) His-bundle pacemaker implantation. (C,D) Corresponding left atrial volume-time curves, which were calculated and plotted in synchrony with the continuously recorded ECG. (C) Pre-implantation tracing with a characteristic double-peak pattern (white arrows) in the volume curve. This reflects two distinct atrial contractions occurring within a single R-R interval due to atrioventricular dissociation. The second peak represents an ineffective atrial contraction against a closed mitral valve. (D) Postimplantation, restoration of atrioventricular synchrony normalized the volume curve, resulting in a single, well-defined peak (white…
Figure 3. Changes in diastolic mitral and tricuspid regurgitation before and after pacemaker implantation, as demonstrated by two-dimensional color flow imaging, color M-mode, and continuous-wave Doppler. (A,B) Two-dimensional color flow imaging: preimplantation DMR and DTR in the apical four-chamber view. (C,D) Color M-mode imaging: mitral regurgitation dynamics pre- and postimplantation. (E,F) Color M-mode imaging: tricuspid regurgitation dynamics pre- and postimplantation. (G,H) Continuous-wave Doppler spectral imaging: preimplantation STR and DTR; postimplantation persistence of only mild STR. (I,J) TDI: changes in mitral annular motion pre- and postimplantation. DMR, diastolic mitral regurgitation; DTR, diastolic tricuspid regurgitation; SMR, systolic mitral regurgitation; STR, systolic tricuspid regurgitation; TDI, tissue Doppler imaging.
Video S1. Diastolic mitral regurgitation before pacemaker implantation as demonstrated by color M-mode imaging (corresponding to Figure 3A).
Video S2. Diastolic tricuspid regurgitation before pacemaker implantation as demonstrated by color M-mode imaging (corresponding to Figure 3B).
Video S3. Diastolic mitral regurgitation eliminated after pacemaker implantation as demonstrated by color M-mode imaging (corresponding to Figure 3D).
Video S4. Diastolic tricuspid regurgitation eliminated after pacemaker implantation as demonstrated by color M-mode imaging (corresponding to Figure 3F).