PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 9, 20260 citationsOpen Access

Friend, not Foe: Lowered Tissue Reactivity to Long-Term Polyimide Implants

View Full Paper
COCorinne OrlemannLSLaura De SantisPNPaul Neering

Key Points

Key points are not available for this paper at this time.

Abstract

One of the biggest challenges for neurotechnology is the design of devices that are tolerated well by brain tissue, without sacrificing functionality and implantability. This study examined which design choices mitigate tissue damage and improve longevity, by varying probe features implanted in the cerebral cortex of mice. We report on a systematic, quantitative analysis of neuronal and inflammation markers across cortical depth. We implanted a total of 103 stiff silicon or flexible polyimide probes in 32 mice, varying their thicknesses and widths, which were either attached to the skull or not. A new, automated workflow to quantify immunohistochemical data examines: 1) the tissue loss caused by the implant, 2) the cortical neuronal density, and 3) the immune response expressed by astrocytic and microglial reaction. Flexible polyimide probes exhibited a clear advantage, with fewer lesions and weaker immune responses than stiff silicon probes. Furthermore, we observed a weaker influence of the shank cross-section. A cortical depth profile of immune reactivity revealed focal reactions at the device entry points in the superficial cortex and at the cortex-white matter boundary. This study gives important insights on optimizing device design parameters as well as surgical insights for improved tissue integration of intracortical electrode arrays.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Orlemann et al. (2026) studied this question.

synapsesocial.com/papers/6a089b5aafa0a1b8dbde0118https://doi.org/10.64898/2026.02.06.703281
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Moment-preserving thresolding: A new approach1985 · 910 citations
  2. 2Reach and grasp by people with tetraplegia using a neurally controlled robotic arm2012 · 2,770 citations
  3. 3Large-scale recording of neuronal ensembles2004 · 1,934 citations
  4. 4Challenges, developments and applications of silicon deep reactive ion etching2003 · 232 citations
  5. 5On the longevity of flexible neural interfaces: Establishing biostability of polyimide-based intracortical implants2022 · 68 citations