May 17, 2026International Journal of Hyperthermia1 citationsOpen Access

Coagulation function changes after high-intensity focused ultrasound therapy for uterine fibroids and adenomyosis: a large retrospective cohort study

View Full Paper
XZXiaofei ZhangJNJingyi NiWXWeiwei Xu

Key Points

  • To investigate the impact of high-intensity focused ultrasound (HIFU) therapy on coagulation function in patients with uterine fibroids and adenomyosis.
  • Retrospective cohort study of 1,189 patients undergoing HIFU treatment from August 2015 to November 2020.
  • Paired t-tests compared coagulation indicators before and after HIFU treatment; multiple logistic regression assessed risks associated with treatment parameters.
  • Follow-up analysis did not report thromboembolism development post-treatment.
  • After HIFU, 61.8% and 55.7% of patients exhibited elevated D-dimer and fibrinogen degradation products (FDP), respectively.
  • The highest exposure energy tertile was associated with a significant increase in the risk of simultaneous elevation of D-dimer and FDP (adjusted OR 4.58 [3.17, 6.66]).
  • Other coagulation indicators indicated a transient hypercoagulable state with prolonged prothrombin time and thrombin time, shortened activated partial thromboplastin time, and decreased platelet count.

Abstract

OBJECTIVE: High-intensity focused ultrasound (HIFU) therapy is increasingly used in the management of various solid tumors. However, limited data are available regarding the association between HIFU treatment and coagulation function. MATERIALS AND METHODS: A total of 1,189 patients diagnosed with uterine fibroids or adenomyosis who underwent HIFU therapy at Shanghai First Maternal and Infant Hospital between August 2015 and November 2020 were included. Paired t-tests were conducted to compare coagulation indicators measured before and after HIFU treatment. Multiple logistic regression models were used to calculate adjusted odds ratios (ORs) and 95% confidence intervals (CIs) to evaluate the association between the risk of elevated D-dimer/fibrinogen degradation products (FDP) and HIFU treatment parameters categorized into tertiles. RESULTS: A total of 1,148 eligible patients were included in the final analysis. After HIFU treatment, 61.8% and 55.7% of patients showed elevated D-dimer and FDP levels, respectively, and 54.6% exhibited simultaneous elevation of both on the first day after treatment. Other post-treatment coagulation indicators also demonstrated a hypercoagulable state, including prolonged prothrombin time and thrombin time, shortened activated partial thromboplastin time, and decreased platelet count. During follow-up, no patients developed thromboembolism. Several HIFU parameters were associated with increased D-dimer and FDP levels. The highest tertile of exposure energy was significantly associated with a greater risk of simultaneous elevation of both D-dimer and FDP (adjusted OR 95% CI: 4.58 3.17, 6.66). CONCLUSION: Higher exposure energy during HIFU treatment may induce alterations in coagulation function, resulting in a transient post-treatment hypercoagulable state.