May 17, 2026Dentomaxillofacial Radiology0 citations

Automated tooth numbering on panoramic radiographs versus cone-beam computed tomographs: A diagnostic accuracy study of a commercial artificial intelligence system

View Full Paper
NSNora SultaniNKNatalia KazimierczakZSZbigniew Serafin

Key Points

  • To evaluate the diagnostic accuracy and reliability of an AI system for automated tooth numbering on two imaging modalities.
  • Retrospective single-centre diagnostic accuracy study involving patients receiving both imaging types in 2024.
  • Index test involved automated tooth numbering by Diagnocat using the Fédération Dentaire Internationale numbering scheme.
  • Performance metrics were assessed using patient-level cluster bootstrap analysis.
  • Accuracy for panoramic radiographs was 99.79% and 99.80% for cone-beam computed tomography.
  • 154 out of 178 (86.5%) panoramic exams and 156 out of 174 (89.7%) cone-beam exams showed completely error-free numbering.
  • A significant gap exists between high accuracy rates and the need for manual corrections in about one in ten cases.

Abstract

Abstract Objectives To assess the diagnostic accuracy of a commercial artificial intelligence system for automated tooth numbering on panoramic radiographs and cone-beam computed tomography and to quantify case-level reliability. Methods In this retrospective single-centre diagnostic accuracy study, consecutive patients who underwent both panoramic radiography and cone-beam computed tomography in 2024 were included. The index test was automated tooth numbering generated by Diagnocat using the Fédération Dentaire Internationale numbering scheme. The reference standard was modality-specific consensus of two experienced, blinded readers. Tooth-position performance metrics with 95% confidence intervals were estimated using patient-level cluster bootstrap. Case-level reliability was defined as the proportion of examinations with completely error-free numbering across all evaluated tooth positions. Results The study analysed 178 panoramic radiographs and 174 cone-beam computed tomography examinations. Tooth-position performance was near-perfect and similar across modalities (overall accuracy 99.79% for panoramic radiographs and 99.80% for cone-beam computed tomography). At the case level, 154/178 (86.5%) panoramic radiographs and 156/174 (89.7%) cone-beam computed tomography examinations were error-free. Conclusions Despite near-perfect tooth-position metrics, approximately one in ten to one in seven examinations required at least one manual correction, demonstrating a gap between granular accuracy and case-level reliability. Advances in knowledge Reporting case-level, error-free outputs alongside tooth-position metrics provides a more clinically meaningful estimate of reliability for automated tooth numbering and supports safer workflow implementation.