ThermiQuant™ AquaStream: A portable instrument for quantitative colorimetric isothermal nucleic acid amplification reactions in paper and tube formats

View Full Paper
BRBibek RautGPGopal PallaJWJiangshan Wang

Key Points

  • The research aims to develop an affordable and portable device that facilitates qualitative and quantitative nucleic acid amplification in varying formats.
  • Developed ThermiQuant™ AquaStream, a portable device for isothermal LAMP reactions in paper and tube formats.
  • The device supports real-time tracking and precise temperature control, with medium-throughput capabilities.
  • Testing was done using synthetic SARS-CoV-2 orf7ab DNA fragments to establish limits of detection and quantification.
  • Achieved a limit of detection of 110 copies/reaction in tube and 39 copies/reaction in µPADs.
  • Establishes limit of quantification at 250 copies/reaction for both formats, with strong linear calibration curves (R² = 0.98 for tubes, R² = 0.96 for µPADs).
  • Demonstrated the versatility of the device for use in diverse diagnostic environments.

Abstract

Microfluidic paper-based analytical devices (µPADs) are an attractive format for colorimetric nucleic acid amplification tests (NAATs) because they enable low-cost, portable diagnostics in resource-limited settings. However, researchers often optimize colorimetric assays in liquid reactions in tubes before translating them to µPADs. Since both formats require separate instruments for incubation and real-time sensing, direct comparison of reactions between the two formats is difficult. To address these cross-platform limitations, we developed ThermiQuant™ AquaStream, a portable benchtop device (15 × 20 × 16 cm, ~ 5 kg; cost: USD 327) that supports seamless colorimetric loop-mediated isothermal amplification (LAMP) reactions in both µPADs and tubes under a common workflow. The system enables real-time reaction tracking (every 30 seconds) through onboard image processing, precise isothermal control (±0.5 °C) using a repurposed consumer-grade sous-vide heater, and medium-throughput (24 tubes or 42 µPADs). Testing with synthetic SARS-CoV-2 orf7ab DNA fragments demonstrated a limit of detection corresponding to a 95% probability of detection (LOD95) of 110 copies per reaction in tube (22 copies/µL) and 39 copies per reaction in µPADs (5 copies/µL), estimated using probit regression. In both formats the limit of quantification (LOQ), defined as the lowest concentration yielding a coefficient of variation (CV) of quantification time (Tq) ≤ 10%, was 250 copies/reaction resulting in a strong linear (R 2 = 0.98 & R 2 = 0.96 respectively for tube and µPADs) standard calibration curves. ThermiQuant™ AquaStream provides an affordable and versatile benchtop platform capable of supporting both tube- and µPAD-based colorimetric LAMP assays, serving as a proof-of-concept research tool for assay development and molecular diagnostics in One Health settings such as clinics, farms, and field environments.