Establishing Age-Specific and Sex-Specific Norms for Mitral Valve E-Point Septal Separation (EPSS) Measurements in Pediatric Patients

View Full Paper
JRJaya C. RuffinCSChristopher T. StemSPScott Pletzer

Key Result

In a sample of 455 pediatric patients, the median mitral valve E-point septal separation (EPSS) was 2.25 mm, which is lower than previously reported values in adults and children.

Key Points

  • This study aims to establish normal EPSS values in pediatric patients to assist in evaluating heart function.
  • Cross-sectional retrospective study involving 455 pediatric patients aged 17 or younger with transthoracic echocardiograms.
  • Patients with reduced ejection fraction or cardiac abnormalities were excluded from the analysis.
  • Evaluated relationships between EPSS and biometric/echocardiographic measurements, with interclass correlation assessed.
  • The median EPSS across all patients was 2.25 mm (IQR 2.06 mm), while the lowest 3 EPSS measurements had a median of 1.33 mm (IQR 2.56 mm).
  • Significant correlations were found between EPSS and age, height, weight, and body surface area (p < 0.05), but not with sex.
  • The interclass correlation coefficient (Cronbach Alpha) for EPSS measurement consistency was 0.951.

Study Design

Type

Observational (n=455)

Multicenter

No

Structured PICO

What are the normal reference values for mitral valve E-point septal separation (EPSS) in pediatric patients?

P
Population
455 pediatric patients aged 17 years or younger who had an outpatient transthoracic echocardiogram, excluding those with reduced ejection fraction and cardiac abnormalities
I
Intervention
Mitral valve E-point septal separation (EPSS) measurement from parasternal long-axis B-mode views
O
Outcome
Normal pediatric EPSS values (median EPSS)surrogate

This study establishes normal reference values for mitral valve E-point septal separation (EPSS) in pediatric patients, finding them to be lower than previously reported in adults and children.

Limitations

  • Single-center retrospective design
  • Differences in imaging and measurement technique may explain observed differences from prior reports

Abstract

Objective: Pediatric heart failure is a rare condition with significant morbidity that requires timely diagnosis and treatment. Mitral valve E-point septal separation (EPSS) may be used as an estimate of systolic function in this evaluation. Although well studied in adults, there is limited literature looking at pediatric EPSS values. The goal of this study was to establish normal pediatric EPSS values that can serve as a reference in this evaluation. Methods: This was a single-center retrospective study of 455 pediatric patients aged 17 years or younger, who had an outpatient transthoracic echocardiogram performed from January 1, 2020, until June 26, 2023. Those with reduced ejection fraction and cardiac abnormalities were excluded. EPSS measurements were taken from parasternal long-axis B-mode views. Relationships between EPSS and patient biometric and echo measurements were evaluated. Consistency of EPSS measurement between independent reviewers was also evaluated. Results: Across all patients, the median EPSS for all measurements was 2.25 mm (IQR 2.06 mm). When looking specifically at the lowest 3 EPSS measurements for each patient, the median EPSS was 1.33 mm (IQR 2.56 mm). EPSS demonstrated statistically significant ( P <0.05) but low magnitude ( R <0.3) correlations with several patient biometric and echo measurements, including a negative correlation with ejection fraction and a positive correlation with age, height, weight, and body surface area. There was no significant correlation with sex. Interclass correlation by Cronbach Alpha was 0.951. Conclusions: EPSS measurements observed in this large pediatric patient sample are lower than those reported in both adults and children. Differences in imaging and measurement technique may explain these observed differences. Future prospective studies are needed to explore these differences and better define reference EPSS values and their clinical implications.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Ruffin et al. (2026) conducted an observational in Pediatric patients (n=455). Mitral valve E-point septal separation (EPSS) measurement was evaluated on Median EPSS for all measurements. In a sample of 455 pediatric patients, the median mitral valve E-point septal separation (EPSS) was 2.25 mm, which is lower than previously reported values in adults and children.