PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 25, 2026Transactions of the Institute of Measurement and Control0 citations

Enhanced stator flux and torque control in isolated wind-driven induction generators using a third-order super-twisting sliding mode controller

View Full Paper
BYBendjeddou YacineSASeghiour AbdellatifSHSellamna Hemza

Key Points

  • This research aims to improve voltage regulation and dynamic performance in isolated wind-driven induction generators using an advanced control strategy.
  • Proposed a third-order super-twisting sliding mode controller for voltage regulation.
  • Conducted comparative simulations with 2-STSMC, fuzzy logic control, and proportional-integral controllers.
  • Evaluated improvements in flux stability, torque smoothness, and harmonic distortion.
  • Achieved a significant reduction in steady-state error and improved dynamic response.
  • Demonstrated a substantial decrease in stator current total harmonic distortion (THD) under disturbances.
  • Confirmed enhanced voltage regulation and dynamic performance in isolated self-excited induction generator systems.

Abstract

The self-excited induction generator (SEIG) is a promising solution for wind energy conversion in isolated and off-grid applications owing to its simplicity, robustness, and low maintenance requirements. However, its terminal voltage is highly sensitive to variations in rotor speed and load, which complicates regulation. This paper proposes a robust control approach based on third-order super-twisting sliding mode control (3-STSMC) to enhance voltage regulation and dynamic performance. The proposed controller regulates both the stator flux and electromagnetic torque to maintain a stable DC-link voltage at the rectifier output, even under significant disturbances. A comprehensive comparative simulation study against 2-STSMC, fuzzy logic control (FLC), and proportional–integral (PI) controllers validates the superior dynamic response, lower steady-state error, and substantial reduction in stator current total harmonic distortion (THD) achieved by the proposed 3-STSMC approach. Simulation results confirm the effectiveness of the proposed technique in improving flux stability, torque smoothness, and total harmonic distortion in isolated SEIG-based wind systems.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Yacine et al. (2026) studied this question.

synapsesocial.com/papers/6a13e81d0e02ee3982d32d22https://doi.org/10.1177/01423312261447936
Ask AI
Helpful
Bookmark
Share
View Full Paper