This study assesses the possibility of identifying non-through defects in dielectric coatings, specifically interfacial defects located at the metal–coating boundary, by means of high-voltage non-destructive testing. It is demonstrated that partial discharges causing characteristic distortions of the applied test-voltage pulse can be used as a reliable diagnostic feature of such defects. Using an equivalent capacitive representation of a defective coating, a relationship is established between the apparent charge and the geometry of the air-filled gap. The proposed approach is supported by COMSOL simulations of the electric-field distribution and by experiments performed on Plexiglas specimens containing blind holes of different depths. In addition, a method is developed for isolating the partial-discharge signal based on a weighted sum of increments in the root-mean-square deviations of the second derivative of the voltage waveform. The resulting relationships enable estimation of the residual coating thickness in the defect region.
Syasko et al. (2026) studied this question.