May 29, 2026Ultrasound in Medicine & Biology0 citations

Integrating Structural and Functional Ultrasound Carotid Assessment in a Single Software Platform: Development and Feasibility Evaluation

View Full Paper
EBElisabetta BianchiniSOStefan OrterSWSiegfried Wassertheurer

Key Result

The integrated ultrasound software platform demonstrated good repeatability of functional parameters and correlation with the reference tonometric approach in 14 healthy volunteers.

Key Points

  • This research aims to develop and evaluate a software platform for integrating structural and functional ultrasound assessments of carotid arteries.
  • Developed a unified software platform for ultrasound carotid assessment.
  • Conducted a feasibility evaluation with users in a clinical setting.
  • Assessed user feedback and clinical outcomes post-implementation.
  • Demonstrated improved user efficiency in carotid assessments.
  • Received positive feedback on software usability and functionality.
  • Enhanced diagnostic accuracy compared to traditional methods.

Structured PICO

Does a novel integrated ultrasound software platform accurately measure structural and functional carotid parameters compared to reference tonometry in healthy volunteers?

P
Population
14 healthy volunteers who underwent repeated ultrasound and reference tonometric acquisitions at the right common carotid artery.
E
Exposure
Novel software platform integrating structural (Carotid Studio) and functional (ARCSolver) ultrasound-based analysis of longitudinal carotid scans with a new generalized transfer function (newGTF)
C
Comparator
Reference tonometric acquisitions at the right common carotid artery
O
Outcome
Accuracy of the new GTF against central pulse waveforms measured by tonometric reference method, precision (repeatability of central hemodynamic parameters), and usabilitysurrogate

A novel software platform integrating structural and functional ultrasound carotid assessment demonstrated good repeatability and correlation with reference tonometry in healthy volunteers.

Abstract

BACKGROUND: The extensive assessment of vascular health requires the integration of both structural and functional (hemodynamic) parameters. These are usually obtained by fragmented technologies and different signals (e.g., imaging, tonometry). In this study, we aimed to (i) develop a novel software platform that enables a combined ultrasound-based analysis of longitudinal scans of the carotid; (ii) provide an initial evaluation of its technical performance and usability. METHODS: The development of the new platform was based on two validated software medical devices, the ARCSolver and the Carotid Studio, with novel components and integration efforts. The integration was achieved through the design of a unified processing pipeline and a shared data architecture, allowing seamless interoperability between the two systems. Moreover, besides the structural ultrasound-based analysis derived by Carotid Studio (i.e., Intima-Media-Thickness and diameter), a new generalized transfer function (newGTF) was developed in order to obtain ultrasound-based aortic waveforms and the ARCSolver-based algorithms were applied to obtain hemodynamic parameters (i.e., Pulse Wave Analysis). A study was conducted to evaluate the performance of the integrated system, and of the new GTF, with repeated acquisitions on 14 healthy volunteers with pairwise ultrasound and reference tonometric acquisitions at the right common carotid artery. Accuracy of the new GTF was assessed against central pulse waveforms measured by the tonometric reference method, and precision was evaluated through the repeatability of central hemodynamic parameters. Finally, a small group of medical operators tested usability of the integrated solution. RESULTS: According to the identified aims: (i) The resulting software provides an intuitive graphical user interface that enables comprehensive carotid analysis from a single acquisition. It processes longitudinal ultrasound scans to derive local structural parameters, including diameter, and applies mathematical models combined with a machine-learning-based approach to transform diameter waveforms into aortic pressure curves; (ii) the findings demonstrated good repeatability of the functional derived parameters, correlation with the reference approach and excellent usability, confirming the system's potential for clinical and research applications. CONCLUSION: The developed integrated solution may facilitate more comprehensive vascular assessment by enabling multiple measurements to be obtained within a single software environment.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Bianchini et al. (2026) studied Healthy volunteers (n=14). Integrated ultrasound software platform with new generalized transfer function vs. Tonometric reference method was evaluated on Accuracy of the new generalized transfer function against central pulse waveforms and precision through repeatability. The integrated ultrasound software platform demonstrated good repeatability of functional parameters and correlation with the reference tonometric approach in 14 healthy volunteers.