Transfemoral valve-in-valve transcatheter aortic valve replacement was described in a patient with a chronic descending thoracic aortic dissection flap.
Case Report (n=1)
Demonstrates the feasibility of transfemoral valve-in-valve TAVR in a patient with a chronic descending thoracic aortic dissection.
Transcatheter aortic valve-in-valve implantation is an established therapy for failed surgical bioprosthetic valves and may obviate the need for reoperative surgery. Despite the routine use of large-bore transfemoral access in endovascular aortic repair, its application in structural heart interventions involving chronic thoracic aortic dissection remains uncommon.1 To date, only 2 cases of transcatheter aortic valve replacement in patients with a chronic descending thoracic aortic dissection have been described.
Pupovac et al. (2026) conducted a case report in Failed surgical bioprosthetic valve and chronic descending thoracic aortic dissection (n=1). Transfemoral Valve-in-Valve Transcatheter Aortic Valve Replacement was evaluated. Transfemoral valve-in-valve transcatheter aortic valve replacement was described in a patient with a chronic descending thoracic aortic dissection flap.