February 2, 2026JACOW0 citationsOpen Access

Status of longitudinal bunch-by-bunch feedback system at the upgraded Advanced Photon Source

View Full Paper
PKPavana KallakuriArgonne National LaboratoryABAdam BrillArgonne National LaboratoryLEL. EmeryUniversity of New Brunswick

Key Points

  • The aim is to mitigate longitudinal coupled-bunch instabilities caused by higher order modes in the APS.
  • Used twelve RF cavities from the original APS RF system.
  • Developed Dimtel iGp12 based longitudinal feedback system.
  • Characterized resonance cavity temperatures under APS conditions.
  • Implemented initial commissioning with phase and energy sensing modes.
  • Reduced growth rates through cavity temperature tuning.
  • Successfully managed residual instabilities using the LFB system.
  • Established feedback configuration allows for effective stability in operations.

Abstract

The upgraded Advanced Photon Source (APS) is using twelve Radio Frequency (RF) cavities from the original APS RF system to compensate for beam energy loss. Undamped higher order modes (HOMs) from these cavities pose a risk of instability under the new APS conditions. Dimtel iGp12 processor-based bunch-by-bunch Longitudinal Feedback (LFB) system is developed to address longitudinal coupled-bunch instabilities caused by HOMs. These instabilities are exacerbated by the reduced synchrotron frequency and faster growth rates in presence of bunch lengthening system. The mitigation strategy involves initially reducing growth rates through precise cavity temperature tuning, followed by employing the LFB system to effectively manage residual growth rates. Resonance cavity temperatures of the HOMs have been characterized under APS conditions, providing a reference for tuning in the upgraded APS operation. The LFB system is designed to operate in both phase and energy sensing modes. This paper presents the feedback configuration, initial commissioning results with phase and energy sensing modes, and the feedback setup for operations.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Kallakuri et al. (2026) studied this question.

synapsesocial.com/papers/6980fcfcc1c9540dea80ec9fhttps://doi.org/10.18429/jacow-napac2025-mop087
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Synchrotron frequency measurements using bunch by bunch longitudinal feedback system in a storage-ring with higher harmonic cavity2026
  2. 2Implementation and Initial Operation of the Bunch-by-Bunch Feedback System at SOLARIS2026
  3. 3Beam measurement during swap-out injection of the APS-U storage ring2026
  4. 4Analysis of Methods for Controlling Multibunch Instabilities in DAFNE1993
  5. 5Experience with a bunch lengthening cavity at the APS2026