Development and in vitro testing of an innovative orthodontic bracket debonding force measurement device

View Full Paper
VMVaradaraju MageshPHPandurangan Harikrishnan

Key Points

  • The aim is to develop and test a device that measures forces during orthodontic bracket removal.
  • Developed a debonding force measurement device incorporating force sensitive resistors.
  • Utilized a 3D printed handle for orthodontic debonding pliers.
  • Tested device efficiency using 20 artificial lower premolar teeth with bonded brackets.
  • Recorded forces from the plier's handles for each sample using integrated software.
  • Least debonding force recorded was 66.67 N; highest was 141.26 N with a mean of 111.61 N.
  • Higher forces were recorded from the upper handle of the pliers than from the lower handle.
  • The device functioned satisfactorily in preliminary in vitro tests.

Abstract

Orthodontic brackets are removed from the teeth surfaces after fixed appliance therapy using debonding pliers, but the applied forces are unknown. There is a need for clinicians to know the debonding forces and so this study was aimed to develop an orthodontic debonding force measurement device and to test it in vitro. The device consists of an Orthodontic debonding plier with 3D printed handle covers to adapt the Force Sensitive Resistors (FSRs) which in-turn is attached to an electronic circuit made with a Printed Circuit Board (PCB) connected with a microcontroller. The forces applied by the plier during removal of orthodontic brackets were captured through an Integrated Development Environment (IDE) software display. The device was tested using 20 artificial lower premolar teeth with brackets bonded on the labial (outer) surface of the teeth. Forces generated from both the handles of the plier were recorded for each sample. The descriptive statistics along with Intraclass Correlation Coefficient (ICC) was performed. Between the tested samples, the least debonding force at the tip of the plier was 66.67 N and highest was 141.26 N with a mean of 111.61 N. Higher forces were recorded in the plier's upper handle which had contact with palm and thumb finger than the lower handle with the remaining finger's contact. The preliminary in vitro testing of the developed orthodontic debonding force measurement device was found functionally satisfactory. The device is simple to use and will be beneficial to the clinicians in monitoring the debonding forces.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Magesh et al. (2026) studied this question.

synapsesocial.com/papers/69e31fcb40886becb653ee7fhttps://doi.org/10.1177/09544119261441343
Ask AI
Helpful
Bookmark
Share
View Full Paper