April 27, 2026ACS Applied Materials & Interfaces3 citations

Tetra-Polyethylene Glycol Hydrogel Coating Enhances the Performance and Stability of Electrochemical Sensors in Complex Biological Matrices

View Full Paper
TNThien Tien NguyenLa Trobe UniversityAMAlexandre X. MendesVPVatsala PithaihLa Trobe University

Key Points

  • This research aims to enhance the performance and stability of electrochemical aptamer-based sensors in complex biological environments.
  • Developed a tetra-poly(ethylene glycol) hydrogel coating for sensors
  • Tested in undiluted saliva and bovine blood at 37 °C
  • Measured drift, signal gain, and fouling effects over an 8-hour duration.
  • Hydrogel-coated sensors showed 5.7% drift compared to 25.1% for unprotected controls
  • Achieved comparable signal gain across tested vancomycin concentrations
  • Demonstrated reduced electrode fouling while maintaining electron transfer.

Abstract

Electrochemical aptamer-based (EAB) sensors promise real-time, reagent-free drug and biomarker monitoring, but protein adsorption and enzymatic degradation of their target-recognizing aptamers rapidly depress their signal and induce drift in complex matrices, such as saliva or undiluted whole blood. Size-excluding hydrogels offer an approach to reducing these effects, but the problem remains of achieving long-duration operation without significantly throttling the analyte transport or electron transfer to the electrode. In response, here we show that a tetra-poly(ethylene glycol) (tetra-PEG) hydrogel coating forms a soft, highly hydrated, ∼31 nm mesh network that excludes large glycoproteins and cellular components, reduces drift while preserving electron transfer, and enables acceptably rapid small-molecule access. Specifically, in undiluted saliva and bovine blood, this coating reduces electrode fouling and helps sustain EAB performance. For example, in undiluted whole blood at 37 °C, hydrogel-protected sensors exhibit lower drift over 8 h (∼5.7 vs ∼25.1% for unprotected controls) while maintaining a comparable signal gain across the tested vancomycin concentrations. It thus appears that the tetra-PEG hydrogel network can balance antifouling efficacy and nuclease resistance with electron transfer compatibility, suggesting that it may prove to be a practical route to long-duration, in-matrix, and, ultimately, in vivo monitoring using EAB sensors.