January 22, 2026JACOW0 citationsOpen Access

Commissioning of a laser wire profile monitor prototype at CSNS

View Full Paper
BZBiao ZhangCCCheming ChenZXZhihong Xu

Key Points

  • To evaluate the commissioning results of a laser wire prototype for measuring negative hydrogen beam profiles at CSNS.
  • Installed laser wire prototype at nine stations
  • Used laser stripping technology for measurement
  • Conducted optimization before scanning
  • Performed data analysis on collected profiles
  • Successfully measured the profile of the 80MeV H- beam
  • Optimizations improved scanning accuracy
  • Data analysis provided insights on beam distribution

Abstract

China Spallation Neutron Source (CSNS) accelerator complex will employ a new superconducting accelerating section to achieve high beam power. To protect the superconducting cavity from contamination, the second phase of the CSNS superconducting linac section will adopt laser stripping technology for transverse distribution measurements of the negative hydrogen beam at nine stations. In 2024, a laser wire(LW) prototype was installed to measure the profile of the 80MeV H- beam. This paper describes the commissioning results of this LW prototype, including the optimization before scanning, and data analysis.