PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 10, 2026International Journal of Technology & Emerging Research0 citationsOpen Access

ANN-Enhanced Adaptive Sliding-Mode Control for STATCOM- Assisted Self-Excited Induction Generator in Wind Energy Conversion Systems

KRKrishna R. ReddyDSDr.J.B.V. SubrahmanyamDRDr. A. Srinivasula Reddy

Key Points

  • The aim is to develop an Adaptive Sliding-Mode Control method using artificial neural networks to improve the performance of wind energy systems.
  • Application of Adaptive Sliding-Mode Control with artificial neural networks
  • Testing conducted using MATLAB/Simulink simulation
  • Focus on transient response, voltage regulation, and reactive power support
  • Comparison with traditional Sliding-Mode Controllers and PI controllers
  • Improved voltage stability with quicker recovery from voltage sags due to faults
  • Reduction in Total Harmonic Distortion and reactive power oscillations
  • Enhanced fault-ride-through capability and smoother control action

Abstract

The study introduces a new Adaptive Sliding-Mode Control approach that involves the application of artificial neural networks in the control of Static Synchronous Compensator systems coupled with Self-Excited Induction Generators of Wind Energy Conversion Systems. The proposed ASMC is guided towards enhancing the voltage regulation, reactive power support and stability at varying wind and fault conditions. The ASMC, in contrast to traditional Sliding-Mode Controllers (SMC) is an adaptive control system applying control gains dependent on system conditions reducing disturbances and improving resilience to parameter uncertainties and disturbances. The overall dq-axis plant model of SEIGSTATCOM system is constructed and simulated in MATLAB/Simulink to test the transient response, power quality and low-voltage ride-through (LVRT) capability. The results of simulation indicate that the ANN-enhanced ASMC has superior voltage stability and faster recovery in 40% voltage sags as a result of three-phase faults, and decreases Total Harmonic Distortion (THD) and reactive oscillations of power. The ANN-ASMC provides a smoother control action, better fault-ride-through, and smoother reactive power compensation in comparison with the SMC and PI controllers, which validates its use in the modern wind power systems that require high reliability and power quality.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Reddy et al. (2026) studied this question.

synapsesocial.com/papers/69d893eb6c1944d70ce04e39https://doi.org/10.64823/ijter.2603003
Ask AI
Helpful
Bookmark
Share
View Full Paper