PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 10, 2026Antimicrobial Stewardship & Healthcare Epidemiology0 citationsOpen Access

Environmental contamination and cleaning practices in long-term care: a transdisciplinary mixed-methods study

MKMorgan J. KatzASAlejandra SalinasHSHeather Stoltzfus

Key Points

  • The aim is to identify barriers to effective environmental cleaning and disinfection in long-term care facilities.
  • Transdisciplinary, mixed-methods design
  • Environmental sampling of high-touch surfaces
  • Focus groups with environmental services staff
  • Observations of cleaning practices
  • Analysis of multi-drug resistant organism burden
  • 76% of patient room samples tested positive for at least one MDRO, with MRSA being the most common
  • Bacterial burden was highest from the area closest to the resident (median of 27.17 CFU/mL/cm²)
  • Only 43% of high-touch surfaces were cleaned according to facility policy
  • Focus group discussions revealed challenges like inconsistent training and communication issues

Abstract

Abstract Objective: To identify system-level barriers to effective environmental cleaning and disinfection in long-term care (LTC) facilities. Design: Transdisciplinary, mixed-methods approach using human factors engineering and environmental sampling to assess environmental cleaning practices and associated multi-drug resistant organism (MDRO) burden in LTC patient rooms and common areas. Setting: Two high-acuity skilled nursing facilities in Maryland. Methods: Environmental sampling of high-touch surfaces (HTSs) was performed in resident rooms, communal areas, and nursing stations. Samples were analyzed for MDROs and overall bacterial burden. System-level barriers were assessed through observations of cleaning and focus groups with environmental services (EVS) staff and supervisors, guided by the Systems Engineering Initiative for Patient Safety (SEIPS) model. Results: Of 123 composite samples of environmental surfaces, 76% of patient room samples were culture positive for 1+ MDRO, with MRSA the most prevalent organism. Quantitative bacterial burden was higher from Composite 1 (the area in the room closest to the resident) than any other composite in the resident room (median of 27.17 CFU/mL/cm 2 vs 4.55 (near door) and 1.22 (bathroom)). Observations indicated significant deviations from cleaning protocols, with only 43% of HTSs cleaned per facility policy. Focus group discussions highlighted systemic challenges, including inconsistent training, frequent interruptions, and poor communication among staff. Conclusions: The findings underscore the burden of MDRO contamination in LTC settings and critical barriers to effective environmental cleaning. Addressing these issues through standardized training with feedback mechanisms, enhanced communication, and leadership engagement is essential for improving infection prevention efforts and resident safety in LTC facilities.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Katz et al. (2026) studied this question.

synapsesocial.com/papers/69d894ec6c1944d70ce05e7chttps://doi.org/10.1017/ash.2026.10324
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Hospital and long-term care facility environmental service workers' training, skills, activities and effectiveness in cleaning and disinfection: a systematic review2022 · 26 citations
  2. 2Prevalence and Outcomes of Multi-Drug Resistant Blood Stream Infections Among Nursing Home Residents Admitted to an Acute Care Hospital2021 · 14 citations
  3. 3Methicillin‐Resistant S taphylococcus aureus Burden in Nursing Homes Associated with Environmental Contamination of Common Areas2012 · 49 citations
  4. 4Using a Human Factors Engineering Approach to Improve Patient Room Cleaning and Disinfection2016 · 30 citations
  5. 5Evaluation of environmental cleaning of patient rooms: Impact of different fluorescent gel markers2018 · 11 citations