April 15, 2026Military Medicine0 citations

Retained Unexploded Ordnance: A Safety Analysis of Diagnostic Ultrasound on Piezoelectric Fuzes

View Full Paper
JKJames KimballCOCole E. OgrydziakJBJason B. Brill

Key Points

  • The analysis aims to evaluate the safety of using diagnostic ultrasound on piezoelectric fuzes in unexploded ordnance contexts.
  • Tested ultrasound effects on internal piezoelectric crystals
  • Assessed acoustic impedance and mechanical damping
  • Compared findings with current imaging guidelines
  • Diagnostic ultrasound did not generate enough voltage to activate the fuzes
  • Significant acoustic impedance mismatch was observed
  • Recommendations for improved safety in surgical planning were indicated

Abstract

Diagnostic ultrasound did not induce sufficient voltage to actuate the internal piezoelectric crystal of the tested fuzes, likely because of significant acoustic impedance mismatch at the munition casing and mechanical damping of the internal crystal. Although current guidelines recommend only plain radiography, these findings suggest that the risk of acoustoelectric detonation is minimal. Diagnostic ultrasound may be considered a safe adjunct for surgical planning in retained UXO scenarios when applied with appropriate standoff techniques.