PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 15, 2026Polymers for Advanced Technologies0 citations

Additively Manufactured Shape Memory Polycaprolactone/Thermoplastic Polyurethane Scaffolds for Bone Tissue Engineering

View Full Paper
MAMaryam Shaker ArdekaniMAMojtaba AnsariASAlireza Sabzevari

Key Points

  • The study aims to develop and assess shape memory polymer scaffolds for bone tissue engineering applications.
  • Fabricated PCL/TPU scaffolds using extrusion-based 3D printing at 80°C.
  • Evaluated physicochemical characteristics, mechanical properties, and biological performance.
  • Conducted FTIR analysis to confirm polymeric blend interactions.
  • Performed compressive tests to assess strength and compliance.
  • Tested biocompatibility using MTT assays and morphological evaluations.
  • PCL scaffolds exhibited the highest compressive strength while TPU showed greater compliance.
  • The 50/50 TPU/PCL blend displayed intermediate mechanical properties.
  • Blended scaffolds demonstrated the highest cell viability and spreading after 7 days.
  • Osteogenic responses improved over culture time, with TPU/PCL scaffolds showing superior ALP activity and mineralization.

Abstract

ABSTRACT Additive manufacturing makes it possible to produce patient‐tailored scaffolds with precisely regulated porosity for bone tissue engineering; nevertheless, stiff polymeric constructs often fail to adapt to complex, irregular defect shapes. In this work, shape memory porous polycaprolactone/thermoplastic polyurethane (PCL/TPU) scaffolds were fabricated via extrusion‐based 3D printing and systematically assessed in terms of physicochemical characteristics, compressive mechanics, and in vitro biological performance. Printing was carried out using molten polymer inks at 80°C in three compositions: 100% TPU (Sample a), 100% PCL (Sample b), and an equal 50/50 TPU/PCL blend (Sample c). FTIR analysis verified the signature functional groups of both polymers, and the lack of additional bands in the blend supported a physical combination rather than a chemical interaction. Morphological evaluation by SEM revealed uniform, well‐formed filaments and fully interconnected square pores. The mean pore size was approximately 497–502 μm, while average filament diameters were about 537 μm for TPU, 563 μm for PCL, and 630 μm for TPU/PCL. Compressive testing showed that neat PCL delivered the greatest strength (yield: 2.68 MPa; ultimate: 9.52 MPa), whereas TPU exhibited markedly higher compliance (yield: 0.051 MPa; ultimate: 0.43 MPa); the 50/50 blend produced intermediate mechanical behavior (yield: 0.75 MPa; ultimate: 1.58 MPa). Biocompatibility with SaOS2 cells was demonstrated through MTT assays (viability > 80% on Day 3 with further improvement by Day 7), DAPI and crystal violet staining, and SEM‐based adhesion observations, with the blended scaffold showing the highest cell density and pronounced spreading. Moreover, osteogenic responses increased with culture time, and the TPU/PCL scaffold yielded the most intense Alizarin Red staining and the highest ALP activity at Days 7 and 14. Overall, these findings suggest that 3D‐printed TPU/PCL scaffolds offer suitable pore architecture, an optimized compressive profile, and improved osteogenic potential, highlighting their suitability as conformable, minimally invasive matrices for bone defect repair.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Ardekani et al. (2026) studied this question.

synapsesocial.com/papers/69df2bece4eeef8a2a6b0dd5https://doi.org/10.1002/pat.70555
Ask AI
Helpful
Bookmark
Share
View Full Paper