PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 15, 2026ACS Nano1 citations

Ultra-Linear Afterglow Oxygen Sensing and Visualization in Morphology-Engineered Phosphorescent Microporous Copolymers

View Full Paper
HSHao SuWHWenhuan HuangBCBiao Chen

Key Points

  • The aim is to develop a method for constructing phosphorescent microporous films that enable ultralinear oxygen sensing.
  • Constructed microporous films using triphenylamine-derived phosphors integrated into amphiphilic copolymers.
  • Utilized both volatile nonazeotropic and azeotropic solvents to foster interconnected microporous networks.
  • Examined phosphorescent properties and oxygen sensing performance through Stern-Volmer analysis.
  • Achieved ultralinear oxygen sensing with R² values exceeding 0.999.
  • Demonstrated high quenching constants (KSV) of up to 2071.
  • Displayed long room-temperature phosphorescence lifetimes (~100 ms) and excellent reproducibility.

Abstract

Phosphorescence-based oxygen sensors offer an efficient route to rapid oxygen visualization, yet their practical deployment is often hindered by nonlinear Stern-Volmer responses and low sensitivity arising from heterogeneous microenvironments in physically mixed systems. Here, we report a scalable morphological-engineering strategy to construct microporous films with room-temperature phosphorescence (RTP) that show ultralinear oxygen sensing. Triphenylamine-derived phosphors are covalently integrated into amphiphilic copolymers composed of hydrophobic and hydrophilic segments, effectively suppressing phosphor aggregation. By judiciously selecting volatile nonazeotropic and azeotropic mixed solvents, we direct the formation of interconnected microporous networks or perforated microcells, thereby dramatically increasing the quenchable phosphorescent fraction. The resulting films exhibit long RTP lifetimes (∼100 ms) and ultralinear oxygen sensing (R2 > 0.999) with Stern-Volmer quenching constants KSV of up to 2071, together with excellent reproducibility. These afterglow microporous films further enable real-time visualization of gas flow and underwater dissolved oxygen monitoring, demonstrating their potential as reliable platforms for high-performance oxygen sensing.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Su et al. (2026) studied this question.

synapsesocial.com/papers/69df2cf7e4eeef8a2a6b20ddhttps://doi.org/10.1021/acsnano.6c00162
Ask AI
Helpful
Bookmark
Share
View Full Paper